![Hilti DS TS20-E Operating Instructions Manual Download Page 27](http://html1.mh-extra.com/html/hilti/ds-ts20-e/ds-ts20-e_operating-instructions-manual_2136337027.webp)
Dismantling the saw system
1. Pivot the saw arm to the 90° position. Switch the machine off, disconnect the cables and fit the protective caps
to the plugs and sockets.
2. Disconnect the water hose from the saw head and clean the blade guard, saw head and rail system.
3. Remove and clean the blade guard and saw blade.
4. Remove the saw head from the rail and clean these parts.
5. Disconnect the cables and water hose from the power supply and fit the protective caps to the plugs and sock-
ets.
6. Clean the cables and hoses, roll them up and attach them securely to the transport trolley.
7. Stow the saw head, rail system parts, blade guard and accessories securely on the transport trolley.
-CAUTION-
■
To avoid the possibility of damage, always switch off at the main switch before disconnecting the power cable.
■
To avoid damage when temperatures below freezing are expected, the cooling system must be fully drained by
blowing out with the pump provided.
5.6
Operation / Maintenance
6. Maintenance
Cleaning
1. Disconnect the system from the electric supply.
2. Clean the entire set of equipment after finishing work or before long breaks between periods of use.
3. Do not allow dirt and slurry to dry out and adhere to the parts.
4. When cleaning, pay particular attention to the operating surfaces, threads, connectors, toothed sections, points
of contact between moving parts, operating controls and safety or operating information plates.
5. Fit the protective caps to all plugs and connectors.
6. Clean the power supply, remote control unit, and cable with a damp cloth.
7. Use a medium-hard brush and water to clean the saw head, rails, blade guard system and transport trolley.
-CAUTION-
■
Do not use high pressure cleaning systems to clean the power supply, saw head, remote control unit or cables.
Water finding its way into these parts may cause malfunctions and damage to the equipment.
■
If concrete formwork parting agent or oil is used on the equipment (to help prevent concrete adhering to it) take
care to ensure that the product used contains no solvents.
■
Products containing solvents may attack and damage the seals or other parts of the casing.
6.1
< 39°F
359293
To avoid damage when temperatures below freezing are expected, the cooling
system must be fully drained by blowing out with the pump provided.