15

on the diamond core drilling machine and begin drilling
(please refer to the operating instructions for the DD
EC-1 diamond core drilling machine).

–  Automatic filter flushing begins (takes about 15 to 20

seconds) when the switch on the DD EC-1 diamond
core drilling machine is not operated for several sec-
onds. The unit supplies no water during this time.

–  After completion of the filter flushing procedure, the

unit is again ready for use and the next drilling oper-
ation can be started (ready mode).

–  Stand-by mode: If the switch on the diamond core

drilling machine is not pressed for a period of more
than 15 minutes, the unit automatically releases pres-
sure and enters stand-by mode. In this case, before
beginning the next drilling operation, the switch on
the diamond core drilling machine must be pressed
briefly in order to re-pressurise the unit. After a few
seconds, the unit is again ready to supply water.

Warning indicators

–  Acoustic warning signal (without warning lamp): This

indicates inadequate water flow which could be caused
by incorrect adjustment of the regulator valve in man-
ual operation or other malfunctions (please refer to
the “Troubleshooting“ section).

–  Water warning lamp 

 

(simultaneous acoustic warn-

ing signal): This indicates inadequate water pressure.
Could be caused by the container being empty, blocked
filter or other malfunctions (see “Troubleshooting” sec-
tion).

–  Temperature warning lamp 

 

(simultaneous acoustic

warning signal): This indicates excessively high water
temperature. Stop using the system immediately (see
“Troubleshooting” section).

–  Water level / slurry volume sight glass 

: This indi-

cates the drilling slurry level and the remaining quan-
tity of water in the container. It provides useful fault-
finding information in case of malfunctions and makes
it possible to estimate the number of holes which can
be drilled before emptying and refilling. Due to wide-
ly varying conditions (diameter, depth, etc.), it is not
possible to give an exact indication of the number of
holes which can be drilled.

Cleaning the container

The container should be emptied and cleaned in the fol-
lowing cases (it is generally recommended that the main
filter is cleaned at the same time): 
–  Malfunctions caused by the slurry level being too high

or the water level being too low (see “Troubleshoot-
ing” section).

–  Unit is switched off permanently (e.g. at the end of

the working day).

–  Remove the container from the housing and open 

it as described above. Observe the safety precau-
tions.

–  Dispose of the container contents in accordance with

the information in the “Disposal” section and under
observance of local regulations.

–  Check the inner and outer cover seals for damage.

Carefully remove dirt from the surfaces of the seals.
Ensure that the main filter is seated securely. Check
that the air release valve moves easily 

.

–  Place the cover on the container. Take care to ensure

that it is positioned correctly, the right way round (the
lugs at both corners of the cover located in the cor-
responding recesses in the container 

and 

). The

nipple block is then positioned at the same side as
the container water level sight glass. When the cov-
er is placed in position, take care to ensure that the
container latches and the float hose are not pinched
between the container and the cover. Care must also
be taken to ensure that the suction hose hangs down
into the water and that the float ball is free to float 

.

–  Close the container latches. To do this, first engage

the latches on the container and then press the latch-
es towards the cover. The container latches must be
heard to engage. It may be necessary to press the
cover down slightly.

– 

Always use all four container latches. Never use 

the unit when the container latches are dam-

aged.

–  Lift the container by its handle and insert it carefully,

the right way round, in the housing. When doing so,
the guide ribs on the container must be carefully insert-
ed into the corresponding openings in the housing. Do
not allow the container to drop into the housing 

.

–  Fold the container handle down to the nipples side

until it is flush with the top surface of the housing. It
may be necessary to press the cover down slightly.

–  Never attempt to fill the unit through the hoses. It

must always be filled as described above.

Operation

–  Check the sight glass 

 

to ensure that sufficient water

is in the container.

–  Connect the unit to the mains supply. Use the supply

cord with the built-in PRCD residual current device
(supplied with the diamond core drilling machine).
Insert the keyed plug in the socket as described above.
Insert the mains plug in the mains socket.

–  Switch on the residual current device by pressing the

green button. The self-test function of the unit is then
activated. All warning lamps light briefly and an acoustic
signal is emitted.

– 

Test the residual current device for correct func-
tionality. To do this, press the black test button.

The ON indicator on the unit must extinguish. After
testing, switch on again by pressing the green  button.

–  Switch on the unit by turning the ON / OFF switch in

a clockwise direction as far as it will go. It then takes
about 20 seconds for the internal parts of the system
to fill with water. During this time, the water supply
system is not fully operational. Subsequently, the
green ON indicator lights to show that the unit is ready
for use.

–  Start the water supply system by operating the switch

on the DD EC-1 diamond core drilling machine. Adjust
the water volume as desired by turning the regulator

Printed: 07.07.2013 | Doc-Nr: PUB / 5139951 / 000 / 00

Summary of Contents for DD-REC 1

Page 1: ...DD REC 1 Bedienungsanleitung de Operating instructions en Mode d emploi fr Brugsanvisning da K ytt ohje fi Bruksanvisning sv Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 2: ...0 1 1 0 1 DD EC 1 0 1 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 3: ...2 0 1 3 0 1 4 5 0 1 DD EC 1 max min 6 9 7 0 1 8 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 4: ...10 11 12 0 1 14 0 1 13 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 5: ...0 Operating controls ON OFF switch ON indicator lamp Water warning lamp Temperature warning lamp Keyed plug connection for electric cable supply cord socket Water level slurry volume sight glass Troll...

Page 6: ...e drilled through hole blind hole Noise information in accordance with EN 61029 Typical A weighted emission sound pressure level LpA 76 dB A 80 dB A Main features of the unit Class I electrical protec...

Page 7: ...the condition of the supply cord with PRCD GFCI residual current device supplied with the DD EC 1 diamond core drilling machine and then check the condition of the unit including the supply cord and...

Page 8: ...ables are used only extension cables of a type approved for the intended use and of ade quate cross section may be used Failure to observe this point may result in reduced performance and could cause...

Page 9: ...damage Carefully remove dirt from the surfaces of the seals Ensure that the main filter is seated securely Check that the air release valve moves easily Place the cover on the container Take care to...

Page 10: ...storing a spare main filter not supplied A spare filter is recomended The container must be removed on order to access the storage location and insert a spare filter Insert the grip section of the spa...

Page 11: ...on at regular intervals Do not operate the unit if parts of it are damaged or when the operating controls do not operate faultlessly The unit should be repaired at a Hilti service centre if necessary...

Page 12: ...of water or other neutralisa tion agent before it is allowed to flow into the sewerage system Solid material from the drilling slurry should be deposited at a construction waste disposal site 18 Retur...

Page 13: ...g valve opened in manual Close the regulating valve on the diamond operation when the diamond core core drilling machine drilling machine is switched off Seals defective Check the seals on the cover a...

Page 14: ...12100 2011 65 EU 2006 95 EC 2004 108 EC Hilti Corporation Feldkircherstrasse 100 FL 9494 Schaan Paolo Luccini Johannes W Huber Head of BA Quality and Process Management Senior Vice President BA Elect...

Page 15: ...23 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2527 0213 00 Pos 5 1 Printed in Liechtenstein 2013 Right of technical and programme changes reserved S E O 33...

Reviews: