Troubleshooting

Fault

Possible cause

Solution

Unit doesn’t start

Fault in mains supply

Plug in another electric appliance and 
check whether it works.

Supply cord or plug defective

The cord should be checked and replaced 
if necessary by an electrical specialist.

Unit defective

The unit should be repaired at a Hilti 
service centre.

Acoustic warning signal 

Core bit or diamond core drilling  Check for free flow and eliminate 

(without warning lamp)

machine blocked

blockage.

Regulating valve on diamond core  Open the regulating valve on the diamond 
drilling machine set too low in 

core drilling machine.

manual operation.
Water supply hose not connected   Connect the water supply hose to the 
to the diamond core drilling 

diamond core drilling machine.

machine.

Water warning lamp lights;  

Too little water or too much 

Clean the container and refill it.

acoustic warning signal

slurry in the container
Inner container not completely

Fill the inner container completely with 

filled with water

water.

Main filter blocked

Regenerate the main filter.

Regulating valve opened in manual  Close the regulating valve on the diamond 
operation when the diamond core   core drilling machine.
drilling machine is switched off
Seals defective

Check the seals on the cover and in the 
nipples for damage and have them 
replaced at a Hilti service centre if 
necessary. 

Container not inserted correctly 

Check the position of the container in the 

in the unit

housing; close the container handle care-
fully. 

Air release valve sticking

Check the air release valve to ensure free 
movement; have it repaired at a Hilti ser-
vice centre if necessary.

Pressure pump defective

Have it repaired at a Hilti service centre.

Temperature warning lamp lights;  Water temperature too high

Allow the container to cool or clean it and 

acoustic warning signal

then refill it. Caution: Risk of burning or 
scalding! 

Suction performance inadequate  Coarse filter in the water

Remove coarse particles.

(leakage at water collector on the  collector of the diamond
diamond core drilling machine)

drilling machine blocked
Suction pump defective

Have it repaired at a Hilti service centre.

The seals of the water tank

Check if the surface and seals of the

don’t seal off completely

cover from the water tank are clean.

Printed: 07.07.2013 | Doc-Nr: PUB / 5139951 / 000 / 00

Summary of Contents for DD-REC 1

Page 1: ...DD REC 1 Bedienungsanleitung de Operating instructions en Mode d emploi fr Brugsanvisning da K ytt ohje fi Bruksanvisning sv Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 2: ...0 1 1 0 1 DD EC 1 0 1 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 3: ...2 0 1 3 0 1 4 5 0 1 DD EC 1 max min 6 9 7 0 1 8 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 4: ...10 11 12 0 1 14 0 1 13 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 5: ...0 Operating controls ON OFF switch ON indicator lamp Water warning lamp Temperature warning lamp Keyed plug connection for electric cable supply cord socket Water level slurry volume sight glass Troll...

Page 6: ...e drilled through hole blind hole Noise information in accordance with EN 61029 Typical A weighted emission sound pressure level LpA 76 dB A 80 dB A Main features of the unit Class I electrical protec...

Page 7: ...the condition of the supply cord with PRCD GFCI residual current device supplied with the DD EC 1 diamond core drilling machine and then check the condition of the unit including the supply cord and...

Page 8: ...ables are used only extension cables of a type approved for the intended use and of ade quate cross section may be used Failure to observe this point may result in reduced performance and could cause...

Page 9: ...damage Carefully remove dirt from the surfaces of the seals Ensure that the main filter is seated securely Check that the air release valve moves easily Place the cover on the container Take care to...

Page 10: ...storing a spare main filter not supplied A spare filter is recomended The container must be removed on order to access the storage location and insert a spare filter Insert the grip section of the spa...

Page 11: ...on at regular intervals Do not operate the unit if parts of it are damaged or when the operating controls do not operate faultlessly The unit should be repaired at a Hilti service centre if necessary...

Page 12: ...of water or other neutralisa tion agent before it is allowed to flow into the sewerage system Solid material from the drilling slurry should be deposited at a construction waste disposal site 18 Retur...