background image

16

–  Rinse out the remaining slurry and, if necessary,

remove dried-on remains. Wipe the inside of the sight
glass with a soft cloth. Clean the surfaces of the seals
on the container carefully 

. Rinse out the con tainer

under running water. Do not use a high-pressure clean-
ing system.

–  Clean the main filter (see below).
–  Fill the container as described above, close it and then

insert it in the housing.

Regenerating the main filter

–  Regeneration of the main filter is recommended in

the following situations:
–  When malfunctions caused by blockage of the main

filter are experienced

–  Each time the container is refilled

–  Remove the container from the housing as described

above and open it. Observe the safety precautions.

–  Unscrew the main filter from the cover. When doing

so, do not hold the filter by the ceramic body. Instead,
grip it only by the grip section on the underside of the
main filter (reduces risk of breakage) 



.

–  Clean the main filter under running water, using the

sandpaper supplied, by rubbing it in a longitudinal
direction on all sides until the light colour of the ceram-
ic body reappears 



.

During this process, the outermost surface of the
ceramic body is rubbed off. This regeneration proce-
dure can be repeated up to about 20 times until the
mini mum wall thickness of the ceramic body is reached.

–  Check the wall thickness of the ceramic body. The

main filter must be replaced as soon as the diameter
of the ceramic body reaches a minimum of 42 mm.
Failure to observe this point could result in cracking
or breakage of the ceramic body 



.

–  Check the main filter. Replace it immediately if cracked

or broken. A defective main filter may cause damage
to the recycling unit and to the diamond core drilling
machine.

–  Screw the main filter into the cover until resistance is

clearly felt. Then continue to turn the filter a further
45° (maximum). Screwing the filter in beyond this
point does not improve the efficiency of the filter seal
and may result in permanent damage to the filter or
cover parts.

–  Fill the container as described above, close it and then

insert it in the housing.

Drying the main filter

–  In rare cases, regeneration of the main filter may not

be sufficient to clear a blockage. Should this be expe-
rienced, allow the main filter to dry for at least 24
hours, standing upright with the thread at the top, in
a warm, dry place before it is reused.

Replacement main filter

–  

The main filter is a wearing part with a limited life
expectancy. The housing has provision for storing a
spare main filter (not supplied). A spare filter is
recomended. The container must be removed on order

to access the storage location and insert a spare  filter.
Insert the grip section of the spare main filter in the
holder in the base of the housing at an angle and then
bring the filter into a vertical position until it engages
with the plastic tab. To remove the spare main filter,
lift the plastic tab slightly and pull the filter out of the
holder to the side.

Switching off after use

–  Before each long break between periods of use (e.g.

after finishing work for the day). The recycling unit
must be switched off as follows:

1. Disconnect the mains plug.
2. Release the hose connectors to the diamond core

drilling machine. Connect the extraction hose and
water supply hose connectors together.

3. Release the keyed plug from the diamond core drilling

machine. To do this, pull on the ring and turn the plug
in a counterclockwise direction, as far as it will go,
and then pull it out.

–  Proceed as follows in order to avoid malfunctions

caused by dirt deposits:

1. Clean the container tank and main filter.
2. Refill with fresh water.
3. Plug the supply cord into the mains socket.
4. Switch on the PRCD by pressing the green button.
5. Switch on the unit by turning the ON/OFF switch in a

clockwise direction, as far as it will go.

6. Run the recycling unit for 10 minutes. Switch the recy-

c ling unit on/off at the main switch four times during
these 10 minutes. This will flush out the internal tub-
ing and valves of the recycling unit.

7. Disconnect the mains plug.
–  Clean the container and regenerate the main filter

.

Transport without wheel assembly

– A handle 

, which can be folded out easily, is pro-

vided for transporting the unit by hand. Grip sections
are provided at the sides for lifting the unit with both
hands. Take care to avoid pinching your fingers at the
grips.

– 

A suitable means (net or straps) must be used 
when the unit is lifted by a crane. The wheel

assembly, housing or container grip must never be
used as a lifting point for a crane hook or other  similar
lifting tackle. When transporting the unit by crane, the
applicable safety regulations must be observed 



.

Transport with wheel assembly

–  Attaching the wheel assembly: Hold the unit against

the guide tubes on the wheel assembly and allow it
to slide down until the catch engages automatically.
Take care to ensure that the feet of the unit are  located
in the corresponding sockets in the wheel assembly



.

–  Wind the hose set around the wheel assembly  handle

for transport. If desired, the toolbox for the DD EC-1
diamond core drilling machine can be placed on the
unit first.

Printed: 07.07.2013 | Doc-Nr: PUB / 5139951 / 000 / 00

Summary of Contents for DD-REC 1

Page 1: ...DD REC 1 Bedienungsanleitung de Operating instructions en Mode d emploi fr Brugsanvisning da K ytt ohje fi Bruksanvisning sv Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 2: ...0 1 1 0 1 DD EC 1 0 1 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 3: ...2 0 1 3 0 1 4 5 0 1 DD EC 1 max min 6 9 7 0 1 8 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 4: ...10 11 12 0 1 14 0 1 13 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 5: ...0 Operating controls ON OFF switch ON indicator lamp Water warning lamp Temperature warning lamp Keyed plug connection for electric cable supply cord socket Water level slurry volume sight glass Troll...

Page 6: ...e drilled through hole blind hole Noise information in accordance with EN 61029 Typical A weighted emission sound pressure level LpA 76 dB A 80 dB A Main features of the unit Class I electrical protec...

Page 7: ...the condition of the supply cord with PRCD GFCI residual current device supplied with the DD EC 1 diamond core drilling machine and then check the condition of the unit including the supply cord and...

Page 8: ...ables are used only extension cables of a type approved for the intended use and of ade quate cross section may be used Failure to observe this point may result in reduced performance and could cause...

Page 9: ...damage Carefully remove dirt from the surfaces of the seals Ensure that the main filter is seated securely Check that the air release valve moves easily Place the cover on the container Take care to...

Page 10: ...storing a spare main filter not supplied A spare filter is recomended The container must be removed on order to access the storage location and insert a spare filter Insert the grip section of the spa...

Page 11: ...on at regular intervals Do not operate the unit if parts of it are damaged or when the operating controls do not operate faultlessly The unit should be repaired at a Hilti service centre if necessary...

Page 12: ...of water or other neutralisa tion agent before it is allowed to flow into the sewerage system Solid material from the drilling slurry should be deposited at a construction waste disposal site 18 Retur...

Page 13: ...g valve opened in manual Close the regulating valve on the diamond operation when the diamond core core drilling machine drilling machine is switched off Seals defective Check the seals on the cover a...

Page 14: ...12100 2011 65 EU 2006 95 EC 2004 108 EC Hilti Corporation Feldkircherstrasse 100 FL 9494 Schaan Paolo Luccini Johannes W Huber Head of BA Quality and Process Management Senior Vice President BA Elect...

Page 15: ...23 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2527 0213 00 Pos 5 1 Printed in Liechtenstein 2013 Right of technical and programme changes reserved S E O 33...