background image

 

 

 

 

T-400-2 

Portable Irrigation Machine 

 

Assembly and Operating Instructions 

 

 
 

 
 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Underhill International Corporation  

Irvine, CA  USA 

866-863-3744 • 

www.underhill.us

 

 

Summary of Contents for Tracker 2 T-400-2

Page 1: ...T 400 2 Portable Irrigation Machine Assembly and Operating Instructions Underhill International Corporation Irvine CA USA 866 863 3744 www underhill us ...

Page 2: ...RODUCTION 3 APPLICATIONS 3 GENERAL INSTRUCTIONS FOR SAFETY AND ACCIDENT PREVENTION 3 BEFORE USE 4 RECOMMENDED TOOLS FOR ASSEMBLY 4 GETTING STARTED 4 WINTERIZATION 7 SPECIFICATIONS 7 PRODUCT DIMENSIONS 7 IMPACT SPRINKLER PERFORMANCE CHART 8 HOSE FRICTION LOSS CHART 8 ...

Page 3: ...g on the water source The Tracker2 comes standard with a part circle impact sprinkler with a radius of 62 feet 18 9m depending on the delivery pressure to the inlet end of the Tracker2 The part circle sprinkler can be converted to a full circle model by sliding the trip pin upwards while the sprinkler is set to the forward mode and not the reverse mode Warning The Tracker2 requires a minimum of 50...

Page 4: ...t sprinkler which is included in the shipping carton but not assembled Getting Started The following are set up instructions of the machine initial and periodic use 1 Locate the sprinkler inlet at the top of the Tracker2 machine see Figure 4 1 Wrap the male end of the impact sprinkler with two full turns of Teflon tape Initially hand thread and tighten the sprinkler into the sprinkler inlet Use an...

Page 5: ...ed and nearest the water supply Consider the radius of the impact sprinkler and delivery pressure to determine the Tracker s final position particularly considering prevailing winds 5 Layout the hose parallel to the travel direction of the Tracker see Figure 5 2 below Now make the hose connection to your water supply Verify the hose is free of dirt debris and sand by flushing the hose from the wat...

Page 6: ...t be OFF while the Quick Closing Valve is opened 9 Open the water supply Verify the working or delivery water pressure and water flow is sufficient The Tracker2 will start to pull itself along the pull cable by the on board turbine and gear box 10 Located at the end of the pull cable is a Stopper see Figure 7 1 This presses the switch off lever to close the quick closing valve once all of the pull...

Page 7: ...have collected within the machine using compressed air This can be accomplished by temporarily removing the impact sprinkler and blowing air back through the hose inlet port Then clean and lubricate wheel axles cable drum pull cable locking mechanism and winder handle connection into the main body of the machine Specifications Product Dimensions Length 32 1 2 0 83m Width 18 0 46m Overall Height w ...

Page 8: ...approx 60 meters 260 approx 80 meters 325 approx 100 meters 1 4 6 4mm 51 Psi 6 0 Psi Loss 15 6 Psi Loss 19 5 Psi Loss 65 Psi 6 2 Psi Loss 16 0 Psi Loss 20 Psi Loss 67 Psi 6 5 Psi Loss 16 5 Psi Loss 21 Psi Loss Notes 1 The Tracker2 requires a minimum of 50 Psi to the inlet end of the machine after all losses calculated through the length of hose to be used 2 diameter 6 4mm nozzle is the standard no...