background image

14

core drilling machine to the rear. Never carry the unit by
the supply cord or hose set and never pull on these parts.
Never drive over the hoses or supply cord. Don’t unplug
the unit by pulling on the supply cord. Don’t expose the
hoses or supply cord to heat, oil or sharp edges. If the
supply cord becomes damaged while working, don’t
touch it – unplug the mains plug immediately and have
the unit or supply cord repaired at a Hilti service centre.
Never expose the plug connections for the unit to water.
If a plug interface has become wet, always disconnect
the supply cord plug from the mains socket before touch-
ing it and wiping it dry. Check that the pins of the plug
and the supply cord are clean and dry before they are
connected. Unplug the supply cord from the mains sock-
et before cleaning.

Avoid unintentional starting.

Always switch off the unit and unplug the 
supply cord from the mains socket before

removing the container, when the unit is not in use (e.g.
during pauses between work), before cleaning and before
carrying out any maintenance.

Keep the unit in good condition.

Follow the instructions on care and maintenance.

Repairs to the unit may be carried out only by an autho-
rised electrical specialist using original Hilti spare parts.
Failure to observe this point may result in damage to the
unit or present a risk of accident. Accordingly, if neces-
sary, have the unit repaired at a Hilti service centre or
authorised Hilti repair workshop. In accordance with
national safety regulations, the safety function of the
earth / ground conductor must be checked at regular
intervals.

Before use

It is essential that the safety precautions print-
ed in these operating instructions are read

and observed. Also read and observe the instructions
and safety precautions listed in the operating instruc-
tions for the DD EC-1 diamond core drilling machine.

The DD-REC1 water recycling system should
be used exclusively with the DD EC-1 dia-

mond core drilling machine and the corresponding sup-
ply cord with built-in PRCD residual current device (sup-
plied with the DD EC-1 diamond core drilling machine).
In Great Britain, the 110 V units must be connected to
an isolating transformer.

The mains voltage must comply with the infor-
mation on the type plate.

If extension cables are used: only extension cables
of a type approved for the intended use and of ade-

quate cross section may be used. Failure to observe this
point may result in reduced performance and could cause
the cable to overheat. Damaged extension cables must
be replaced.

The recommended cable cross sections and maximum
lengths are as follows:

Mains 

Conductor cross section

voltage

1.5 mm

2

2.0 mm

2

2.5 mm

2

3.5 mm

2

100 V

20 m

40 m

110 V

20 m

40 m 

220–230 V

50 m

80 m

Operation

Connecting the hose set to the drilling machine

–  

Connect the keyed electric supply cord plug from the
hose set to the socket on the underside of the drilling
machine. To do this, bring the marks on the plug and
the socket into alignment and then push the plug into
the socket on the machine as far as it will go. While
maintaining slight pressure on the plug, rotate it in a
clockwise direction until it is heard to engage 

.

–  Connect the thin end of the hose from the hose set to

the drilling machine and the thick end of the hose to
the water collector hose connector. The couplings
must be heard to engage when connected.

Removing and opening the container

– 

Never remove the container while the unit is 

switched on. Switch the unit off by turning the 

on / off switch in a clockwise direction and discon-
nect the mains plug 

.

– 

Wear protective gloves and protec-

tive goggles. The contents of the container may irri-

tate the skin and eyes. The container and its contents
may be hot after long periods of use. Observe the
safety precautions. When handling the container, take
care to avoid pinching your fingers at the edges of the
housing, grips and latches.

–  Lift the container grip approx. 45° and hold it in this

position until pressure compensation is heard to be
complete (approx. 2 seconds). Failure to observe this
point may cause a large quantity of the container con-
tents to escape at the nipples.

–  Lift the container grip to the vertical position and pull

the container upwards out of the housing 

.

–  Always transport the container in an upright position

or place it on a horizontal surface.

–  Ensure that it stands securely.
–  Open the four container cover latches 

.

–  Lift the cover off the container, taking care to ensure

that the float ball doesn’t get stuck. Lay the cover down
carefully.

Filling, closing and inserting the container

–  Fill the inner container up to the top edge with clean

water 

. Fill the outer container to the desired level

between the min. and max. marks.

Printed: 07.07.2013 | Doc-Nr: PUB / 5139951 / 000 / 00

Summary of Contents for DD-REC 1

Page 1: ...DD REC 1 Bedienungsanleitung de Operating instructions en Mode d emploi fr Brugsanvisning da K ytt ohje fi Bruksanvisning sv Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 2: ...0 1 1 0 1 DD EC 1 0 1 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 3: ...2 0 1 3 0 1 4 5 0 1 DD EC 1 max min 6 9 7 0 1 8 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 4: ...10 11 12 0 1 14 0 1 13 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 5: ...0 Operating controls ON OFF switch ON indicator lamp Water warning lamp Temperature warning lamp Keyed plug connection for electric cable supply cord socket Water level slurry volume sight glass Troll...

Page 6: ...e drilled through hole blind hole Noise information in accordance with EN 61029 Typical A weighted emission sound pressure level LpA 76 dB A 80 dB A Main features of the unit Class I electrical protec...

Page 7: ...the condition of the supply cord with PRCD GFCI residual current device supplied with the DD EC 1 diamond core drilling machine and then check the condition of the unit including the supply cord and...

Page 8: ...ables are used only extension cables of a type approved for the intended use and of ade quate cross section may be used Failure to observe this point may result in reduced performance and could cause...

Page 9: ...damage Carefully remove dirt from the surfaces of the seals Ensure that the main filter is seated securely Check that the air release valve moves easily Place the cover on the container Take care to...

Page 10: ...storing a spare main filter not supplied A spare filter is recomended The container must be removed on order to access the storage location and insert a spare filter Insert the grip section of the spa...

Page 11: ...on at regular intervals Do not operate the unit if parts of it are damaged or when the operating controls do not operate faultlessly The unit should be repaired at a Hilti service centre if necessary...

Page 12: ...of water or other neutralisa tion agent before it is allowed to flow into the sewerage system Solid material from the drilling slurry should be deposited at a construction waste disposal site 18 Retur...

Page 13: ...g valve opened in manual Close the regulating valve on the diamond operation when the diamond core core drilling machine drilling machine is switched off Seals defective Check the seals on the cover a...

Page 14: ...12100 2011 65 EU 2006 95 EC 2004 108 EC Hilti Corporation Feldkircherstrasse 100 FL 9494 Schaan Paolo Luccini Johannes W Huber Head of BA Quality and Process Management Senior Vice President BA Elect...

Page 15: ...23 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2527 0213 00 Pos 5 1 Printed in Liechtenstein 2013 Right of technical and programme changes reserved S E O 33...

Reviews: