Intended uses

The unit is intended for the following uses

–  Extraction of drilling slurry and supplying water and

power to the DD EC-1 diamond core drilling machine
for drilling in mineral materials (reinforced concrete,
masonry and natural stone)

–  The unit may be operated only when standing on a

horizontal surface and in an upright position.

–  Clean water should be used as the cooling and flush-

ing medium.

The water recycled by the unit is almost entirely
free of particles but may contain substances released

by the material in which the hole is drilled. Under no cir-
cumstances should this water be considered suitable
for use as drinking water.

Accessories

–  

Replacement main filter, item number 377255 (wear-
ing part)

Eye protection
must be worn.

Protective gloves

must be worn.

Safety precautions

When using the unit, the following fundamental safety
precautions must always be observed in order to avoid
the risk of injury, electric shock and fire hazards. Please
read and observe the instructions before using the unit.

Wear suitable working clothing.

Wear shoes with non-slip soles.

Make the working area safe.

Objects which could cause injury should be removed
from the working area. Ensure that the area is well lit.
When working, keep other persons, children in partic-
ular, away from the unit.

Take the influences of the surrounding area into account.

Do not expose the unit to rain or snow and do not oper-
ate it in damp or wet environments or in the vicinity of
flammable liquids or gases.

Check the unit each time before use.

First check the condition of the supply cord with

PRCD/GFCI residual current device (supplied with the
DD EC-1 diamond core drilling machine) and then check

the condition of the unit, including the supply cord and
the plug (an integral part of the hose set, except for the
GB version). Do not operate the unit if any parts of it are
found to be damaged, if the unit is not complete or when
the operating controls cannot be operated faultlessly.

Use the correct accessories.

Use only the recommended original Hilti accessories.

Use the unit only for the purposes for which it is  intended.

Apply a safe working method.

Always ensure that you have a safe stance

and that the unit is standing securely. On scaffolding or
similar platforms, the unit should be used without the
wheel assembly. Never stand on the unit. The wheel
assembly, housing and container grips should never be
used as attachment points for lifting by a crane hook or
similar means. If the unit is to be transported by crane,
the applicable safety regulations must be observed.
Ensure that the unit, supply cord and hose set are posi-
tioned where they are free of obstructions. When work-
ing, always guide the hose set away from the diamond

Use 
protective
equipment.

Do not, under any circumstances, use this prod-
uct in any way other than as described in these
operating instructions.

Drilling slurry and recycled drilling water may irritate the
skin and eyes. Rinse with water immediately after skin
contact. If allowed to come into contact with the eyes,
rinse with plenty of water and consult a doctor. The water,
container and hoses may become very hot after long
periods of use and present a risk of burning or scald-
ing.

Read the operating

instructions

Printed: 07.07.2013 | Doc-Nr: PUB / 5139951 / 000 / 00

Summary of Contents for DD-REC 1

Page 1: ...DD REC 1 Bedienungsanleitung de Operating instructions en Mode d emploi fr Brugsanvisning da K ytt ohje fi Bruksanvisning sv Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 2: ...0 1 1 0 1 DD EC 1 0 1 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 3: ...2 0 1 3 0 1 4 5 0 1 DD EC 1 max min 6 9 7 0 1 8 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 4: ...10 11 12 0 1 14 0 1 13 Printed 07 07 2013 Doc Nr PUB 5139951 000 00...

Page 5: ...0 Operating controls ON OFF switch ON indicator lamp Water warning lamp Temperature warning lamp Keyed plug connection for electric cable supply cord socket Water level slurry volume sight glass Troll...

Page 6: ...e drilled through hole blind hole Noise information in accordance with EN 61029 Typical A weighted emission sound pressure level LpA 76 dB A 80 dB A Main features of the unit Class I electrical protec...

Page 7: ...the condition of the supply cord with PRCD GFCI residual current device supplied with the DD EC 1 diamond core drilling machine and then check the condition of the unit including the supply cord and...

Page 8: ...ables are used only extension cables of a type approved for the intended use and of ade quate cross section may be used Failure to observe this point may result in reduced performance and could cause...

Page 9: ...damage Carefully remove dirt from the surfaces of the seals Ensure that the main filter is seated securely Check that the air release valve moves easily Place the cover on the container Take care to...

Page 10: ...storing a spare main filter not supplied A spare filter is recomended The container must be removed on order to access the storage location and insert a spare filter Insert the grip section of the spa...

Page 11: ...on at regular intervals Do not operate the unit if parts of it are damaged or when the operating controls do not operate faultlessly The unit should be repaired at a Hilti service centre if necessary...

Page 12: ...of water or other neutralisa tion agent before it is allowed to flow into the sewerage system Solid material from the drilling slurry should be deposited at a construction waste disposal site 18 Retur...

Page 13: ...g valve opened in manual Close the regulating valve on the diamond operation when the diamond core core drilling machine drilling machine is switched off Seals defective Check the seals on the cover a...

Page 14: ...12100 2011 65 EU 2006 95 EC 2004 108 EC Hilti Corporation Feldkircherstrasse 100 FL 9494 Schaan Paolo Luccini Johannes W Huber Head of BA Quality and Process Management Senior Vice President BA Elect...

Page 15: ...23 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2527 0213 00 Pos 5 1 Printed in Liechtenstein 2013 Right of technical and programme changes reserved S E O 33...

Reviews: