8.3 Checking the power tool after care and

maintenance

After carrying out care and maintenance work on the

power tool, check that all protective and safety devices

are fitted and that they function faultlessly.

9 Troubleshooting

Fault

Possible cause

Remedy

The power tool doesn’t start.

Interruption in the electric supply.

Plug in another electric appliance and

check whether it works.

The supply cord or plug is defective.

Have it checked by a trained electrical

specialist and replaced if necessary.

The carbon brushes are worn.

Have it checked by a trained electrical

specialist and replaced if necessary.

The power tool doesn’t achieve

full power.

The extension cord’s conductor cross

section is inadequate.

Use an extension cord with an ade-

quate conductor cross section.

10 Disposal

Most of the materials from which Hilti power tools or appliances are manufactured can be recycled. The materials

must be correctly separated before they can be recycled. In many countries, Hilti has already made arrangements for

taking back your old power tools or appliances for recycling. Please ask your Hilti customer service department or

Hilti representative for further information.

11 Manufacturer’s warranty - tools

Hilti warrants that the tool supplied is free of defects in

material and workmanship. This warranty is valid so long

as the tool is operated and handled correctly, cleaned

and serviced properly and in accordance with the Hilti

Operating Instructions, and the technical system is main-

tained. This means that only original Hilti consumables,

components and spare parts may be used in the tool.

This warranty provides the free-of-charge repair or re-

placement of defective parts only over the entire lifespan

of the tool. Parts requiring repair or replacement as a

result of normal wear and tear are not covered by this

warranty.

Additional claims are excluded, unless stringent na-

tional rules prohibit such exclusion. In particular, Hilti

is not obligated for direct, indirect, incidental or con-

sequential damages, losses or expenses in connec-

tion with, or by reason of, the use of, or inability to

use the tool for any purpose. Implied warranties of

merchantability or fitness for a particular purpose are

specifically excluded.

For repair or replacement, send the tool or related parts

immediately upon discovery of the defect to the address

of the local Hilti marketing organization provided.

This constitutes Hilti’s entire obligation with regard to

warranty and supersedes all prior or contemporaneous

comments and oral or written agreements concerning

warranties.

en

13

Printed: 09.12.2013 | Doc-Nr: PUB / 5164435 / 000 / 00

Summary of Contents for DAG 500-D

Page 1: ...DAG 500 D Operating instructions en Mode d emploi fr Manual de instrucciones es Printed 09 12 2013 Doc Nr PUB 5164435 000 00 ...

Page 2: ...1 This Product is Certified Ce produit est homologué Producto homologado por Este produto está registrado C US Printed 09 12 2013 Doc Nr PUB 5164435 000 00 ...

Page 3: ...2 3 4 5 6 7 Printed 09 12 2013 Doc Nr PUB 5164435 000 00 ...

Page 4: ... 8 10 9 PP PP 11 Printed 09 12 2013 Doc Nr PUB 5164435 000 00 ...

Page 5: ... 12 13 Printed 09 12 2013 Doc Nr PUB 5164435 000 00 ...

Page 6: ...ns In these operating instructions the designation the power tool always refers to the DAG 500 D angle grinder Operating controls and components 1 Ventilation slots Hold to run switch Side handle Spindle lockbutton Guard release button Spindle Guard Clamping flange Cutting disc grinding disc not supplied Clamping nuts Wrench Safety release 1 General information 1 1 Safety notices and their meaning...

Page 7: ...rriage is mandatory for cutting stone The working environment may be as follows construction site workshop renovation conversion or new construction The power tool may be operated only when connected to a power supply providing a voltage and frequency in compliance with the information given on its type identification plate Working with metals Cutting grinding brushing Working with mineral materia...

Page 8: ...and max cable lengths Conductor cross section 14 AWG 12 AWG Mains voltage 110 120 V 75 ft 125 ft Do not use extension cords with 16 AWG conductor cross section 2 5 Using extension cords outdoors When working outdoors use only extension cords that are approved and correspondingly marked for this application 2 6 Using a generator or transformer This power tool may be powered by a generator or transf...

Page 9: ...or stone These serve to protect the operator and increase the life of the power tool and disc used 2 10 Guard with side cover 5 CAUTION When grinding with straight grinding discs and cutting with cutting discs in metalworking applications use the guard with cover plate 2 11 Front cover for the disc guard 6 CAUTION When grinding with straight grinding discs and cutting with cutting discs in metalwo...

Page 10: ... thread X X X X X X L Clamping flange not for use with accessories with integrated thread X X X X X X 4 Technical data Right of technical changes reserved Power tool DAG 500 D Rated voltage 120 V Rated current input 8 5 A Rated frequency 60 Hz Rated speed 11 000 min Cutting disc Diameter Max 5 Dimensions L x H x W without hood 289 mm 11 38 x 103 mm 4 06 x 82 mm 11 4 in x 4 1 in x 3 2 in Weight wit...

Page 11: ...A moment of inattention while operating power tools may result in serious personal injury b Use personal protective equipment Always wear eye protection Protective equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Prevent unintentional starting Ensure the switch is in the off position before connecting t...

Page 12: ...sk hearing protectors gloves and workshop apron capable of stopping small abrasive or workpiece fragments The eye protection must be capable of stopping flying debris generated by various operations The eye protection must be capable of stopping flying debris generated by various opera tions The dust mask or respirator must be capable of filtrating particles generated by your operation Pro longed ...

Page 13: ...perations a Do not jam the cut off wheel or apply excessive pressure Do not attempt to make an excessive depth of cut Overstressing the wheel increases the loading and susceptibility to twisting or binding of the wheel in the cut and the possibility of kickback or wheel breakage b Do not position your body in line with and behind the rotating wheel When the wheel at the point of operation is movin...

Page 14: ... other masonry products and natural stone arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce exposure to these chemicals the operator and bystanders should work in a well ventilated area work with ap proved safety equipment such as respiratory pro tection appropriate for the type of dust generated and ...

Page 15: ...into the guard mount on the power tool 1 Fit the guard onto the drive spindle collar so that the two triangular marks on the guard and on the power tool in alignment 2 Press the guard onto the drive spindle collar press the guard release button and then rotate the guard until it engages and the guard release button jumps back to its outset position 6 2 2 Adjusting the guard 8 1 Press the guard rel...

Page 16: ...ol to be used safely and without fatigue in all positions e g on off switch facing upwards the gearing section can be rotated to one of four positions at 90 intervals 1 Disconnect the supply cord plug from the power outlet 2 Clean the power tool 3 Remove the side handle from the power tool 4 Remove the four screws from the gearing section 5 Rotate the gearing section to the desired position withou...

Page 17: ... to run switch and then press the switch fully 2 When the hold to run switch is released the safety interlock returns automatically to the locked posi tion 8 Care and maintenance CAUTION Disconnect the mains plug from the power outlet 8 1 Care of the power tool DANGER Under extreme conditions when used for working on metal conductive dust may accumulate inside the tool This may have an adverse eff...

Page 18: ...rer s warranty tools Hilti warrants that the tool supplied is free of defects in material and workmanship This warranty is valid so long as the tool is operated and handled correctly cleaned and serviced properly and in accordance with the Hilti Operating Instructions and the technical system is main tained This means that only original Hilti consumables components and spare parts may be used in t...

Page 19: ...chaan Tel 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 3200 1213 00 Pos 3 1 Printed in Germany 2013 Right of technical and programme changes reserved S E O 382623 A2 Printed 09 12 2013 Doc Nr PUB 5164435 000 00 ...

Reviews: