Technical Data
62/64
COM-C | Communication Module
DOC021001DG12EN | Revision 12 | English | 2011-06 | Released | Public
© Hilscher, 2002-2011
Environmental Conditions
Standard
Test
Test
level
Error
Class
IEC 60068-2-1 Ad
Cold immunity
Min. operating temperature
standard
extended
+0°C / 16h
-20°C / 16h
A
IEC 60068-2-2 Bd
Dry heat immunity
Max. operating temperature
standard
extended
+60°C / 16h
+70°C / 16h
A
IEC 60068-2-3 Ca
Humidity immunity
Operating humidity
standard
extended
+60°C / 24h / 85%
+70°C / 24h / 85%
non condensing
A
IEC 60068-2-1 Ab
Cold withstand
Min. storage temperature
standard
extended
-25°C / 24h
-40°C / 24h
A
IEC 60068-2-2 Bb
Dry heat withstand
Max. storage temperature
standard
extended
+70°C / 24h
+85°C / 24h
A
IEC 60068-2-30 Db
Humidity withstand
Storage humidity
+60°C / 24h / 95%
non condensing
A
Table 43: Product Tests – Environment Conditions
Mechanical Tests
IEC
60068-2-6
Fc
Vibration 10-150
Hz
+ 0.075 mm / 10
m/s2
IEC 60068-2-27 Ea
Shock
150 m/s2 / 11ms
Table 44: Product Tests – Mechanical Tests
Safety
Standard
Test
Max.
Voltage
Pollution
degree
EN 60947
Rated insulation voltage
500 V
1
UL94V0
PCB-Material,
Connectors
Table 45: Product Tests – Safety