Technical Data
59/64
COM-C | Communication Module
DOC021001DG12EN | Revision 12 | English | 2011-06 | Released | Public
© Hilscher, 2002-2011
7 Technical
Data
Operating Condition
Minimum
Maximum
Operating temperature [° C]
COM-C
Standard
Extended (Note 1)
0°
C
-20° C
+60° C
+70° C
Storage temperature [° C]
Standard
Extended
-25°
C
-40° C
+70° C
+85° C
Operating voltage [V]
U1
U2
U3
+3.1 V
11.0 V
29.5 V
+3.5 V
25.0 V
31.6 V
Typical Maximum
Operating current [mA]
COM-Cx-ASM U1
U3
280 mA
50 mA
400 mA
70 mA
COM-Cx-COS
COM-Cx-COM
U1
240 mA
400 mA
COM-Cx-DNS
COM-Cx-DNM
U1
U2
170 mA
20 mA
300 mA
55 mA
COM-Cx-EN
U1
310 mA
400 mA
COM-Cx-DPM
U1
340 mA
400 mA
COM-Cx-DPS
U1
300 mA
400 mA
COM-Cx-IBS
U1
450 mA
1150 mA
COM-Cx-CCS
U1
400 mA
500 mA
COM-CN-SCEB
U1
550 mA
700 mA
Table 38: Technical Data – Operating Conditions
Note 1:
Modules for extended temperature for the module COM-C have the extension ‘-E’ in
the module name. Currently the modules types COM-Cx-DPM-E and COM-Cx-COM-E
are available for extended temperature range. For other types please contact us.