Technical Data
149/223
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM46EN | Revision 46 | English | 2015-12 | Relelased | Public
© Hilscher, 2008-2015
CIFX 70E-CO,
CIFX 70E-CO\MR
Parameter
Value
Transmission Rate
2 GBit/s
Data Access
DPM or DMA (Direct Memory Access)
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
CANopen
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
CANopen Master,
CANopen Slave
Transmission rate
10 kBit/s, 20 kBit/s, 50 kBit/s, 100 kBit/s,
125 kBit/s, 250 kBit/s, 500 kBit/s, 800 kBit/s, 1 MBit/s
Interface Type
ISO-11898, refer to section
CANopen Interface
, page 107.
Galvanic Isolation
optically isolated
Isolation Voltage
1000 VDC (tested for 1 minute)
CANopen Interface
Connector
DSub male Connector, 9 pin
SYS
System Status LED
CAN
CANopen Status (duo LED)
Display LED
Display
The meaning of the CAN LED depends on the loaded
firmware. Refer to chapter
LED Descriptions
, page 80.
Supply Voltage
+3.3 V dc ±5 %, refer to section
Power Supply and Host
Interface
, page 34.
Maximum Current at 3.3 V
(typically)
800 mA
Power supply
Connector
Via PCI Express Bus
Operation
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Operating temperature range*
0 °C ... +65 °C
*Air flow during measurment
0,5m/s
Storage temperature range
0 °C ... +70 °C
Environmental
Conditions
Humidity
10 … 95% relative humidity, no condensation permitted
Dimensions (L x W x H)
119,0 x 69,0 x 18,5 mm
Mounting/Installation
PCI Express x1 slot (3.3 V), refer to section
Slot for the PC
Cards cifX PCI, PCIe and Low Profile PCIe
, page 33.
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)
EN 61000-4-5:2006 (Surge test)
EN 61000-4-6:2009 (to conducted disturbances, induced
by radio- frequency fields)
EN 61000-4-8:2010 (power frequency magnetic field test)
EN 61000-6-2:2005 + B1:2011 (for industrial
environments)
Configuration Software
Master and Slave
SYCON.net
Configuration
Configuration Software Slave
netX Configuration Tool
Table 116: Technical Data CIFX 70E-CO, CIFX 70E-CO\MR