LED Descriptions
100/223
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM46EN | Revision 46 | English | 2015-12 | Relelased | Public
© Hilscher, 2008-2015
8.19 CANopen Slave
For the CANopen Slave protocol, the communication status LED
CAN
can
assume the states described below. This description is valid from stack
version V3.4.
LED
Color
State
Meaning
cifX with 1 Communication Status LED
(current Hardware Revision)
Duo LED red/green
(green)
On
OPERATIONAL:
The device is in the OPERATIONAL state.
(green)
Blinking
(2.5 Hz)
PREOPERATIONAL:
The device is in the PREOPERATIONAL state.
(green)
Single flash
STOPPED:
The device is in STOPPED state.
(red/green)
Flickering
(10 Hz)
Auto Baud Rate Detection active:
The Device is in the auto baud rate
detection mode.
(red)
Single flash
Warning Limit reached
: At least one of the error counters of the CAN
controller has reached or exceeded the warning level (too many error
frames).
(red)
Double flash
Error Control Event
: A guard event (NMT Slave or NMT Master) or a
heartbeat event (Heartbeat consumer) has occurred.
(red)
On
Bus Off
: The CAN controller is in bus OFF state.
CAN
(off)
Off
RESET:
The device is executing a reset or the device has no
configuration.
Table 68: States of the CAN LED for the CANopen Slave protocol – 1 Communication
Status LED (current Hardware Revision)
LED State
Definition
On
The indicator is constantly on.
Off
The indicator is constantly off.
Flickering
(10 Hz)
The indicator turns on and off with a frequency of 10 Hz: “on” for 50 ms, followed by “off” for 50
ms.
Blinking
(2.5 Hz)
The indicator turns on and off with a frequency of 2,5 Hz: “on” for 200 ms, followed by “off” for
200 ms.
Single Flash
The indicator shows one short flash (200 ms) followed by a long “off” phase (1,000 ms).
Double Flash
The indicator shows a sequence of two short flashes (each 200 ms), separated by a short off
phase (200 ms). The sequence is finished by a long “off” phase (1,000 ms).
Table 69: LED state definitions for the CANopen Slave protocol
* Descriptions for 2-Communication Status LEDs of earlier device revisions are included
in the user manual for PC cards cifX fieldbus up to manual rev. 23.