Technical Data
126/223
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM46EN | Revision 46 | English | 2015-12 | Relelased | Public
© Hilscher, 2008-2015
CIFX 50-DN
Parameter
Value
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
64 KByte
Bus Type
PCI, according to [bus spec 1], refer to section
Overview
,
page 114.
Transmission Rate
33 MHz
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
DeviceNet
Communication
Supported communication
standard/ protocol (determined by
the loaded firmware)
DeviceNet Master,
DeviceNet Slave
Transmission rate
125 kBit/s, 250 kBit/s, 500 kBit/s
Interface Type
ISO-11898 according to DeviceNet specification,
refer to section
DeviceNet Interface
, page 108.
Galvanic Isolation
optically isolated
Isolation Voltage
1000 VDC (tested for 1 minute)
DeviceNet Interface
Connector
CombiCon male Connector, 5 pin
SYS
System Status LED
MNS
Module Network Status (duo LED)
Display LED
Display
The meaning of the MNS LED depends on the loaded
firmware. Refer to chapter
LED Descriptions
, page 80.
Supply Voltage
+3.3 V dc ±5 %, refer to section
Power Supply and Host
Interface
, page 34.
Maximum Current at 3.3 V
(typically)
650 mA
Power supply
Connector
Via PCI Bus
Operation
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Operating temperature range*
-20 °C ... +70 °C
(
acc. to UL: 0 °C ... +55 °C
)
*Air flow during measurment
0,5m/s
Storage temperature range
-10 °C ... +70 °C
Humidity
10 … 95% relative humidity, no condensation permitted
Environmental
Conditions
Environment
For UL compliant usage:
The device must be used in a pollution degree 2
environment.
Dimensions (L x W x H)
120,0 x 86 x 18,5 mm (from hardware revision 5)
Mounting/Installation
PCI slot (3.3 V), refer to section
Slot for the PC Cards cifX
PCI, PCIe and Low Profile PCIe
, page 33.
Device
RoHS Yes
CE Sign
Yes
Emission
EN 55011:2009 + A1:2010, CISPR 11:2009, Class A
(Radio disturbance characteristics - Limits and methods of
measurement)
CE Sign
Immunity
EN 61000-4-2:2009 (Electrostatic discharge test)
EN 61000-4-3:2006 + A1:2008 + A2:2010 (Radiated,
radio-frequency, electromagnetic field test)
EN 61000-4-4:2004 + A1:2010 (Burst Electrical fast
transients/burst test)