Technical Data
145/223
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM46EN | Revision 46 | English | 2015-12 | Relelased | Public
© Hilscher, 2008-2015
10.1.20 CIFX 100EH-RE\CUBE
CIFX 100EH-RE
Parameter
Value
Name CIFX
100EH-RE
Part No.
9016.090
Description
PC Card cifX PCI Express for Real-Time Ethernet Master
or Slave, (low-profile card) exclusively for the installing in
KEBA KeControl industry PCs series CP 3XX (Cube).
Part
Function
Communication interface with PCI Express and
Ethernet interface
Communication
Controller
Type netX
100
processor
RAM
8 MB SDRAM
FLASH
4 MB serial Flash EPROM
Integrated Memory
Size of the Dual-Port Memory
64 KByte
Bus Type
PCI Express, One Lane Port*, (refer to section
Overview
,
page 114 and
Pin Assignment for PCI Express Bus CIFX
100EH-RE\CUBE
, page 115.
*The PC card CIFX 100EH-RE\CUBE can be used for x4
connectors, but not a real x4 connection (mechanical deviation
from the standard, it is used only 1 lane).
Transmission Rate
2 GBit/s
Data Access
DPM or DMA (Direct Memory Access)
System Interface
Width for the data access to the
Dual-Port Memory (DPM)
32-Bit
EtherCAT Master, EtherCAT Slave
EtherNet/IP Scanner (Master),
EtherNet/IP Adapter (Slave),
Open Modbus/TCP
POWERLINK Controlled Node/Slave
PROFINET IO-Controller (Master),
PROFINET IO-Device (Slave)
sercos Master, sercos Slave
Supported Real-Time Ethernet
communication systems
(determined by the loaded
firmware)
VARAN Client (Slave)
Ethernet
Communication
Ethernet Frame Types
Ethernet II
Transmission rate
100 MBit/s,
10 MBit/s (depending on loaded firmware)
Interface Type
100 BASE-TX,
10 BASE-T (depending on loaded firmware),
refer to section
Ethernet Interface
, page 105.
Galvanic Isolation
isolated
Isolation Voltage
1000 VDC (tested for 1 minute)
Half duplex/Full duplex
depending on loaded firmware,
supported (at 100 MBit/s)
Auto-Negotiation
depending on loaded firmware
Auto-Crossover
depending on loaded firmware
Connector
2* RJ45 Socket
Ethernet Interface
Channel 0 and 1
With loaded EtherCAT Master firmware only the RJ45
channel 0 can be used, channel 1 is deactivated.
Beginning with the EtherCAT Master firmware version 3
channel 1 can be reactivated if redundancy is activated.
For Open Modbus/TCP with V2.3.4.0 and higher both
RJ45 channels can be used.