background image

User manual

NFD-3090-PNS-IOLM\W

netFIELD IO-Link Wireless Master PROFINET IO-Device

Hilscher Gesellschaft für Systemautomation mbH

www.hilscher.com

DOC201101UM03EN | Revision 3 | English | 2022-02 | Released | Public

Summary of Contents for 1912.102

Page 1: ...r manual NFD 3090 PNS IOLM W netFIELD IO Link Wireless Master PROFINET IO Device Hilscher Gesellschaft f r Systemautomation mbH www hilscher com DOC201101UM03EN Revision 3 English 2022 02 Released Pub...

Page 2: ...mitted write and delete accesses 14 3 6 Information and data security 14 4 Getting started 15 5 Requirements 16 5 1 Hardware and system requirements 16 5 2 Software requirements 16 6 Mounting and demo...

Page 3: ...X O PQI 100 10 1 3 Process data of submodules IO Link Wireless Device X I PQI 101 10 1 4 Process data of submodules IO Link Wireless Device X O PQI 102 10 1 5 Port Qualifier Information 103 10 1 6 Pro...

Page 4: ...lient 127 13 Dimensions 128 13 1 Dimensions netFIELD IO Link Wireless Master device 128 14 Approvals 129 14 1 FCC ISED 129 15 Appendix 131 15 1 References 131 15 2 Conventions in this manual 132 15 3...

Page 5: ...107 added Diagnosis Section PROFINET IO Device status page 119 updated section Wireless port status page 120 updated Technical data Section Technical data device page 124 updated Sections Technical da...

Page 6: ...e netFIELD Wireless Web Server enables you to parameterize the IO Link Devices connected via a wireless connection to the IO Link Wireless Master device Or you can use the IO Link engineering tool IO...

Page 7: ...NFD 3090 PNS IOLM W Manufacturer product identification and technical data can be found on the device housing as laser engravings NFD 3090 PNS IOLM W Hardware installation and commissioning DOC201101...

Page 8: ...nna for IO Link wireless connection to the IO Link Devices 1 to 8 IO Link SMA antenna page 12 16 X2 Connector for SMA antenna for IO Link wireless connection to the IO Link Devices 9 to 16 21 X3 Conne...

Page 9: ...y If a hardware installation is available for the firmware update these specifications are relevant Model Description Part number Hardware revision NFD 3090 PNS IOLM W netFIELD IO Link Wireless Master...

Page 10: ...rt number 1912 102 Character R and hardware revision number R4 Serial number 020000 MAC ID 00 02 A2 02 20 E3 2nd line URL link to product homepage Example 1912 102 R4 20000 00 02 A2 02 20 E3 https www...

Page 11: ...M12 L coded plug 5 pin 4 FE 1 2 3 4 FE M12 L coded socket 5 pin 4 FE 1 1L 24 V DC supply voltage U1L for system and sensor actuator 2 2L Reference potential for 2L 3 1L Reference potential for 1L 4 2...

Page 12: ...mounted 2 7 Derating Note the derating when using the netFIELD IO Link Wireless Master device when you connect a device to Power Out at the device and thus a larger current is passed through the devic...

Page 13: ...eives process data from the connected IO Link Device sensor and sends this data to a higher level control system The IO Link Wireless Master device sends process data received from the higher level co...

Page 14: ...ation or changing the name of station leads to the maximum number of permitted write delete accesses being exceeded and to device damage For example if the configuration is changed once an hour the ma...

Page 15: ...supply units of the device and of the IO Link Device Connections page 21 Commissioning In the configuration software of the PROFINET IO Controller Configure the PROFINET IO Controller Import the GSDML...

Page 16: ...Use type Wifi Antenna 2 4G rubber antenna model TLW25A SMA Male only see section IO Link SMA antenna page 12 Additional components Ethernet network switch For commissioning PC or notebook with at lea...

Page 17: ...eration Mounting instructions Observe the following points when selecting the mounting location When mounting outside buildings Mount the device in such a way that it is protected from weathering espe...

Page 18: ...h is screwed into a mounting hole Section Technical data page 124 contains the specification of the tightening torque Note Note that the device requires a connection to FE functional earth plate at th...

Page 19: ...eve If the device was in operation let it cool down before touching it or use gloves Disconnect the part of the plant to which you have mounted the device from the power supply If the device is dirty...

Page 20: ...usehold waste This product must be disposed of at a designated waste electronic equipment collecting point Waste electronic equipment may not be disposed of as household waste As a consumer you are le...

Page 21: ...refer to Technical data Connection example with W Bridge The connection example described hereafter shows a typical installation that uses a W Bridge to connect a wired IO Link Device via a wireless...

Page 22: ...22 146 7 1 Connection example Figure 4 Connection example with W Bridge NFD 3090 PNS IOLM W Hardware installation and commissioning DOC201101UM03EN Revision 3 English 2022 02 Released Public Hilscher...

Page 23: ...ntroller imports the GSDML file and the user can make the configuration settings and parameterizations for the device The user loads the configuration to the PROFINET IO Controller The PROFINET IO Con...

Page 24: ...nication is used settings of the MQTT Client parameters PDCT GSDML IO Link E T Tool chain 2 Configuration software for the PROFINET IO Controller with PDCT GSDML Configuration of the input output data...

Page 25: ...he PROFINET IO Controller Yes PDCT GSDML IO Link E T Yes Yes Yes IODD netFIELD Wireless Web Server to configure MQTT only Use IO Link E T only Use IO Link E T only experts Yes Tool chain 3 Configurati...

Page 26: ...ROFINET IO communication starts the PROFINET IO Controller transmits the configuration and parameters to the NFD 3090 PNS IOLM W device Parameters for the IO Link Wireless Master or the wireless ports...

Page 27: ...S EXPERT YYYYMMDD xml This file is to be used if settings of the Wireless Master Parameters are made using the configuration software of the PROFINET IO Controller Select the GSDML file PDCT or Expert...

Page 28: ...IO Link Wireless master fixed 2 input bytes und 2 output bytes 1 2 Configuration port WP01 To configure the wireless IO Link port WP01 WP16 specify which IO Link Device type is connected to the port S...

Page 29: ...16 bytes input data and port qualifier information 16 bytes 1 byte PQI no IO Link 8 I PQI IO Link with 8 bytes input data and port qualifier information 8 bytes 1 byte PQI no IO Link 4 I PQI IO Link...

Page 30: ...ess Device X O PQI PDCT Expert X 1 2 4 8 16 32 In the configuration one submodule is configured for each used wireless IO Link port WP PDCT Parameter group Parameter Default Value range Description Wi...

Page 31: ...nnels 3 78 2403 2478 MHz The channels 1 2401 MHz 2 2402 MHz 79 2479 MHz and 80 2480 MHz cannot be used Pairing timeout 5 5 60 Timeout for pairing in seconds IO Link Wireless Track 1 3 configuration Tr...

Page 32: ...check No Device check There is no device check for validation or backup of connected IO Link Devices default Type compare no Backup Restore A device check is performed for validation of connected IO L...

Page 33: ...s Unique ID of the W Device Byte 5 0 0 255 UniqueID of the W Device Wireless Unique ID of the W Device Byte 6 0 0 255 UniqueID of the W Device Wireless Unique ID of the W Device Byte 7 0 0 255 UniqueI...

Page 34: ...Time base is 1 min 5 255 Reserved reserved do not use Table 18 Time base of I Am Alive time The Multiplier has the value range of 1 255 The I Am Alive time is calculated by multiplying the Time base...

Page 35: ...the Wireless Master uses the Minimum I Am Alive time as resulting I Am Alive time Maximum I Am Alive time 10 minutes If the calculated I Am Alive time is greater than the Maximum I Am Alive time the e...

Page 36: ...y settings page 47 MQTT Client and connection configuration MQTT configuration page 48 User administration Setting up and managing users Log in or User administration page 39 Sign in Sign out User log...

Page 37: ...Web Server and the device you want to connect to are both on the same Ethernet subnet Proceed as follows Enter the following text in the address line of your web browser to address the device http Con...

Page 38: ...technology Specification of the radio connection Device version The name and version number of the device the Master and the radio module the web page version Maintenance information Maintenance infor...

Page 39: ...n If you have entered a known user name correctly you now can work with the netFIELD Wireless Web Server with the defined rights of this user The user role Operator Maintenance Admin used for sign in...

Page 40: ...s depend Users can be divided into three roles Maintenance Operator Administrator Creating a new user When opening the user administration the following picture appears Figure 7 User Administration sc...

Page 41: ...proceed as follows Click the red square with a white cross to the right of the user to be removed The user will be deleted The root user cannot be deleted so the red delete button is grayed out NFD 3...

Page 42: ...enu on the Configure IP parameters Store maintenance information Upgrading the firmware Resetting the device to factory settings MQTT configuration page 48 8 3 6 1 IP parameters Select Settings in the...

Page 43: ...or the location where the device is mounted Character string max 32 characters Installation date Date of installation or commissioning of this device Valid installation date Contact information Textua...

Page 44: ...lick Apply Your changes take effect 8 3 6 3 Firmware update The netFIELD Wireless Web Server provides a way to update all firmware required for the IO Link Wireless Master NFD 3090 PNS IOLM W device v...

Page 45: ...e of your device prior to the update including the previously used firmware Changes to settings require operator or admin rights If these are not available the Firmware update tab is grayed out and ca...

Page 46: ...pdate was finished and the device will be restarted after pressing OK and has a new possibly different IP address Click OK Then you must perform the port configuration once again NFD 3090 PNS IOLM W H...

Page 47: ...ettings and IO Link master settings within OPC UA Delete stored network adapter settings Network adapter settings communication settings IP address configuration Name of Station Delete stored applicat...

Page 48: ...on establishment in progress 2 TCP Connected TCP connection established MQTT connection in progress 3 MQTT Connected MQTT connection established 4 Disconnecting MQTT connection shutdown in progress 5...

Page 49: ...nection1 IP settings Open the Connection1 sub tab The IP settings sub sub tab appears by default Figure 15 MQTT tab Connection1 IP settings sub sub tab example Parameter Description Value Value range...

Page 50: ...to the broker which have changed since the last connection Note that if you use this setting the broker must support the preserve context function Enabled default Disabled MQTT Keep Alive Time Second...

Page 51: ...connection when an MQTT Disconnect packet was not sent to the broker If left empty the string Disconnected is sent Text of uppercase and lowercase letters and underscore Default not specified Will QoS...

Page 52: ...the MQTT client waits for the duration of Connection Timeout until a new connection is established to the broker Specified in s 0 MQTT client constantly tries to establish a connection to the broker...

Page 53: ...tab you can make the IO Link Wireless Master configuration settings This includes the specific master settings parameters the activating or deactivating of wireless tracks WT1 WT3 as well as specifica...

Page 54: ...WLAN Channel 13 List of WLAN channels 01 to 13 on the 2 4 GHz frequency band The radio symbols indicate whether a channel is activated and if fully or partly Use mouse over to indicate the help text c...

Page 55: ...3 78 2403 2478 MHz can be configured to be used or not for IO Link wireless communication within a Wireless Master Frequency Hopping is used for transmission on different frequency channels on the 2 4...

Page 56: ...ration 56 146 Figure 20 Channel selection tab Expert settings example NFD 3090 PNS IOLM W Hardware installation and commissioning DOC201101UM03EN Revision 3 English 2022 02 Released Public Hilscher 20...

Page 57: ...ltiple Access FDMA technology If checked this option is used checked unchecked default Reconnect If checked reconnection trials will be performed when connections are lost checked default unchecked WT...

Page 58: ...uccessfully appears Master configuration failed error handling When the IO Link Wireless Master went to an error status a red triangle icon appears for Master in the left column of the netFIELD Wirele...

Page 59: ...er Description Value Value range Index Device index 0 20 Unique ID Identification of the found IO Link Device as unique ID UUID 9 Bytes Copy note the unique ID This value is required for port configur...

Page 60: ...on Scan finished number of found devices device s found For scan errors appears Scan failed HTTP Error error number short description of error plus a further message in the upper part of the scan tab...

Page 61: ...ndor name Vendor text Product name Product ID Product text Serial number Hardware revision Firmware revision Status Displays port status information Port state Port quality Revision ID Master cycle ti...

Page 62: ...e read using common OnRequestData Read mechanism Vendor name Detailed name of vendor of connected device Character string up to 64 characters Vendor text Additional vendor information of the connected...

Page 63: ...y the connected device It indicates software revision running on the connected device 0 No device connected Others Revision ID of connected device Master cycle time Cycle time of communication in Oper...

Page 64: ...sed for the connection from this port to the device Inactive The port is inactive Port ready The port is ready Communication ready The device is ready for communication Operate The device is in commun...

Page 65: ...me of the port is set depending on the selected operating parameters See table Calculation of the port cycle time of the IO Link Wireless Master page 66 Time base Used time base for the calculation of...

Page 66: ...as value or text in brackets e g Port cycle time Free running Settings Validation level Open the Validation level sub tab Figure 27 Settings tab Validation level sub tab example Parameter Description...

Page 67: ...dation and backup possible values If necessary set the expected port parameters Vendor ID and Device ID Settings Transmission Open the Transmission sub tab Figure 28 Settings tab Transmission sub tab...

Page 68: ...for the OPERATE mode The I Am Alive time is calculated by multiplying the time base with the time multiplier 1 664 10 min for higher values an error message appears Default 3 sec Time base Used time...

Page 69: ...eturned with an error C0000124 appears Select the Time base and the Time multiplier for the IMA Time calculation in order to avoid exceeding the maximum allowed value The result is indicated as value...

Page 70: ...port mode was set correctly Pairing by button Now press the button on the wireless device or on the bridge Keep the button pressed at least for 5 seconds Then click Pair by Button Keep the button on t...

Page 71: ...ars Figure 31 Pairing successfully finished Unpair device Click UNPAIR The connected wireless device is unpaired Remove device Click Remove The connected wireless device is removed Port mode is set to...

Page 72: ...roperly or must be brought into a safe operating state Invalid firmware Loading invalid firmware files could render your device unusable Only load firmware files to the device that are valid for this...

Page 73: ...3 146 Figure 32 IOLWD update tab IOLWD firmware successfully updated example NFD 3090 PNS IOLM W Hardware installation and commissioning DOC201101UM03EN Revision 3 English 2022 02 Released Public Hils...

Page 74: ...rmat refer to the IO Link specification Required rights Changes to settings require operator or admin rights If these are not available the ISDU tab is grayed out and the displayed values cannot be ed...

Page 75: ...bindex Read failed IOLMErrorCode error code of the IO Link master IOLDErrorCode error code of the IO Link Device Information on the meaning of the error codes of the IO Link master IOLMErrorCode and d...

Page 76: ...of the IO Link master IOLDErrorCode error code of the IO Link Device Delete the history of read and write accesses To clear the logged history of read and write accesses Click Clear history The histo...

Page 77: ...ault value here is 00 In case of input errors an error message appears Click on Read The read access is executed An entry with a time stamp is written to the history at the bottom of the ISDU tab If t...

Page 78: ...cess is performed If the execution was successful the text Write ok and the result is displayed in the history The entries in the history then have the following structure Time PortId ArgBlockId Write...

Page 79: ...process data input and output values from and to a connected IO Link Device Parameter Description PD input data Process Data input data to the connected IO Link Devices PD input valid Binary coded Po...

Page 80: ...software see description below Setting the IP address with the Ethernet Device Configuration software Start the Ethernet Device Configuration software Check whether the checkmark for option DCP is se...

Page 81: ...IP address for the standard gateway is optional Use Store settings temporary to select whether the IP address is to be set permanently or temporarily Click Ok The device is now accessible via its IP a...

Page 82: ...D Wireless Web Server the following requirements must be fulfilled The device must be mounted wired and supplied with power A browser is required to connect to the netFIELD Wireless Web Server A login...

Page 83: ...peration Parameter Possible value for commissioning Note Master ID 1 Enter the Master ID this way 1 Pairing Timeout 5 seconds Advanced Connectivity intended for future use WT1 Track Mode Cyclic WT2 Tr...

Page 84: ...rt The scan result is displayed The connected device is found The following scan result values are displayed Parameter Scan result example Note Index 0 Unique ID 0x03 0xf3 0x00 0x00 0x01 0x72 0xc0 0x4...

Page 85: ...PNS IOLM W device Port cycle sub tab The Port cycle sub tab includes the parameters Port mode and Port cycle time Figure 41 Settings tab Port cycle sub tab example Parameter Example value for commiss...

Page 86: ...Validation and backup Default No device check Vendor ID 0x0136 Example device Device ID 0x0174 Example device Table 47 Settings Validation level example values Enter the Vendor ID and Device ID of th...

Page 87: ...issioning Note Maximum PD Segment Length 2 Max process data transmissible via IO Link as in the example device used If this maximum value of the used device is not available enter 32 Slot number 0 Tra...

Page 88: ...n number must be assigned as value for the slot IMA Time 3 sec Time base 1 sec Time multiplier 3 Default value is used Low power device No Table 49 Settings Miscellaneous example values Enter the Uniq...

Page 89: ...IELD Wireless Web Server Open the Status tab The following port status data are the values displayed after configuration steps for the IO Link Wireless Master and the port configuration are completed...

Page 90: ...n tab The following device information data are example values displayed after configuration steps for the IO Link Wireless Master and the port configuration are completed Figure 47 Information tab De...

Page 91: ...vice Otherwise you might be forced to send in your device for repair Important If you update the firmware of the NFD 3090 PNS IOLM W device and you did not make a backup of the firmware and configurat...

Page 92: ...o read data from the IO Link Device click Read The time stamp and the corresponding data are displayed in ASCII format below For detailed descriptions on the ISDU tab see Device ISDU page 74 Read writ...

Page 93: ...To read data from the IO Link Wireless Master device click Read The time stamp and the corresponding data are displayed in ASCII format below For detailed descriptions on the ISDU tab with option Tig...

Page 94: ...t is configured Track Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 0 W device with double slot free free free free free free 1 free free free free free free free free Table 51 Track and Slo...

Page 95: ...has the permission to write 9 8 1 Connecting with device Requirements You have an OPC UA client For write access to the device You know the user name and password and you have the permission to write...

Page 96: ...he area Authentication Settings select the option Username Password if you want to execute a write access to the device or select Anonymous if a read access is sufficient If you have selected the opti...

Page 97: ...P server ptbtime2 ptb de of the Physikalisch Technische Bundesanstalt in Braunschweig with the IP address 192 53 103 104 Converting an IP address into a decimal number To convert the IP address to a d...

Page 98: ...IP address of the substitude NTP server Click Call If the function call was successful the output field to the right of Status in the area Output Arguments displays 0 A green bar with the text succee...

Page 99: ...the input process data or the output process data of the submodule IO Link Wireless Master PDCT Expert Byte offset Byte count Process data input Description 1 2 2 byte Input data 2 bytes 0 reserved 3...

Page 100: ...te IOCS Consumer status of output data of this submodule For a description see table Provider and consumer status page 103 Table 55 Input data of submodule IO Link Wireless Device X I X O PQI PDCT Exp...

Page 101: ...O Link Device X 1 1 byte PQI PQI For a description see table Port Qualifier Information page 103 X 2 1 byte IOPS Provider status of input data of this submodule For a description see table Provider an...

Page 102: ...er status page 103 Table 59 Input data of submodule IO Link Wireless Device X O PQI PDCT Expert Byte offset Byte count Process data output Description 1 X X byte Output data X bytes The length X is 1...

Page 103: ...ce error 0 No error warning occurred 1 Error warning occurred at the port or IO Link Device 7 PQ Validity of the process data 0 Invalid I O process data from the IO Link Device 1 Valid I O process dat...

Page 104: ...P address 4840 For IP address use the IP address of the device The client can access device parameters anonymously read only or with user name password read and write The user name and password are se...

Page 105: ...63 Device identification 10 2 2 Identification of connected IO Link Devices The device provides nodes for the identification of connected IO Link Devices For example the OPC UA client can read the ve...

Page 106: ...er fallback Optional additional IP address if the NTP server cannot be reached via the IP address in the NtpClientServerIpAddress node The IP address must be converted into a decimal number The calcul...

Page 107: ...teway Identification prefix iolink v1 gateway capabilities Capabilities of the gateway IODD supported MQTT supported For an example see Gateway Capabilities prefix iolink v1 gateway configuration Netw...

Page 108: ...Protocol allowing automatic assignment of IP addresses DCP PROFINET defines the Discovery and Configuration Protocol a link layer protocol that allows the manual assignment of IP addresses Table 69 G...

Page 109: ...or an example see Port Capabilities prefix iolink v1 masters MASTER_NUMBER ports PORT_NUMBER status Read current status of the port Status Info IO Link revision master cycle time Example prefix iolink...

Page 110: ...Activated statusInfo DEVICE_ONLINE Deactivated statusInfo DEACTIVATED deviceAlias Possible values for deviceAlias Distance_sensor Pressure_sensor Switching_sensor Empty_port Table 71 Port List JSON k...

Page 111: ...DEVICE_ONLINE iolinkRevision 1 1 masterCycleTime value 5 0 unit ms Port Configuration JSON key Values mode DEACTIVATED IOLINK_CYCLIC IOLINK_ROAMING validationAndBackup NO_DEVICE_CHECK TYPE_COMPATIBLE...

Page 112: ...13 14 15 16 17 18 deviceAlias Distance_sensor_1 Example for the cycle time object JSON object value 5 0 unit ms Port Data Storage Example for the port data storage JSON object header vendorId 15 devi...

Page 113: ...alue Read process data output value from the device Set Data IO Link IQ value Example prefix iolink v1 devices master1port4 processdata setdata value For an example see Device Process Data Output ioli...

Page 114: ...e 12 22 216 iqValue false setData iolink valid true value 128 221 134 iqValue false Device Process Data Input JSON object Example for the device process data input JSON object JSON key Description get...

Page 115: ...134 iqValue false Device Events JSON object Example for the device events JSON object JSON key Description time Time severity Severity origin Origin message Message Table 80 Device Events JSON object...

Page 116: ...lientMode INACTIVE Table 82 MQTT Configuration JSON key Example for the MQTT configuration JSON object clientMode ACTIVE serverAddress 192 168 2 1 mqttserver username iolink_json password 123456 lastW...

Page 117: ...firmware update is being installed gray Off No supply voltage No supply voltage for the device or hardware defect During a firmware reset Table 84 States of the SYS LED LED state Definition Blinking T...

Page 118: ...error during initialization red On IO Link Wireless Master critical error gray Off IO Link Wireless Master off or not initialized Table 86 APL LED states 11 1 3 Supply voltage status The supply volta...

Page 119: ...n for 500 ms followed by off for 500 ms Flashing 2 Hz The LED turns on and off with a frequency of 2 Hz on for 250 ms followed by off for 250 ms Table 89 Definition LED states communication status Eth...

Page 120: ...01 WP16 indicate the states for the wireless ports 1 16 as described below LED Color State Description WP01 WP16 Duo LED red green yellow yellow red and green simultaneously green On Port operational...

Page 121: ...ss to IO Link Device IO Link Device is disconnected from Bridge Error Check connection from IO Link Device to the Bridge 0xFFB1 Max Retry error indicating a packet loss The W Master cannot send a mess...

Page 122: ...olerance of 2L voltage 0x6000 Device software fault Error Check firmware revision 0x6320 Parameter error Error Check data sheet and values 0x6321 Parameter missing Error Check data sheet 0x6350 Parame...

Page 123: ...r See manual of the used IO Link Device Any other code Reserved See manual of the used IO Link Device Table 96 IO Link Device Event Codes common NFD 3090 PNS IOLM W Hardware installation and commissio...

Page 124: ...tus failure red green BF Bus failure red green Ethernet LINK X31 Link status connector X31 green ACT X31 Activity status connector X31 yellow LINK X32 Link status connector X32 green ACT X32 Activity...

Page 125: ...63000 2018 Compliance with EMC CE sign yes UKCA sign yes Approvals FCC FCC ID 2ANEG002 ISED IC ID 24152 0002 RED Certificate In preparation Firmware download Web pages netFIELD Wireless Web Server Con...

Page 126: ...cal data protocol Parameter Value Input data 8 bytes 568 bytes including IOPS and IOCS Output data 8 bytes 552 bytes including IOPS and IOCS Alarm types Process Alarm Diagnostic Alarm Identification M...

Page 127: ...sessions 2 Number subscriptions per session 2 Number Monitored Items per session 20 Data coding UA binary Table 102 OPC UA Server 12 6 MQTT Client Parameter Description MQTT Client Client services Pub...

Page 128: ...ireless Master device Figure 56 Dimensions NFD 3090 PNS IOLM W device Tolerance The overall tolerance of the dimensions is 0 2 mm NFD 3090 PNS IOLM W Hardware installation and commissioning DOC201101U...

Page 129: ...hanges or modifications could void the user s authority to operate the equipment ISED Warning Hilscher Gesellschaft f r Systemautomation mbH n approuve aucune modification apport e l appareil par l ut...

Page 130: ...ny other antenna or transmitter Le pr sent appareil est conforme l exposition aux radiations FCC ISED d finies pour un environnement non contr l et r pond aux directives d exposition de la fr quence d...

Page 131: ...Safety standards American National Standards Institute Inc American National Standard Product Safety Information in Product Manuals Instructions and Other Collateral Materials ANSI Z535 6 2016 English...

Page 132: ...hazardous situation which if not avoided may result in minor or moderate Injury Indicates a property damage message Table 104 Signal words Signs Sign Note Safety sign Warning principle General note U...

Page 133: ...2 3 Part 17 Specific conditions for Broadband Data Transmission Systems ETSI EN 301489 17 V3 2 4 ETSI EN 301489 17 V3 2 4 Human exposure restrictions for electromagnetic fields EN IEC 62311 2020 EN 62...

Page 134: ...efore we cannot assume any guarantee or legal responsibility for erroneous information or liability of any kind You are hereby made aware that descriptions found in the user s manual the accompanying...

Page 135: ...e and or software in connection with Flight control systems in aviation and aerospace Nuclear fission processes in nuclear power plants Medical devices used for life support and Vehicle control system...

Page 136: ...due to violations against our operating regulations or against rules of good electrical engineering practice or if our request to return the defective object is not promptly complied with Costs of su...

Page 137: ...pecified in this agreement The customer must not use this confidential information to his own advantage or for his own purposes or rather to the advantage or for the purpose of a third party nor must...

Page 138: ...ther brands mentioned are property of their respective owner of the rights Any company names and product designations provided in this document may be brands company names or trademarks of the corresp...

Page 139: ...Figure 20 Channel selection tab Expert settings example 56 Figure 21 IO Link Wireless Master Configuration tab 57 Figure 22 Scan tab 59 Figure 23 Scan tab scan result 59 Figure 24 Information tab Dev...

Page 140: ...re 48 ISDU tab read write IO Link Device parameters 92 Figure 49 ISDU tab read write IO Link Wireless Master parameters 93 Figure 50 Node NtpClientUpdateConfiguration 1 97 Figure 51 Node NtpClientUpda...

Page 141: ...ormation 43 Table 23 Options to delete settings 47 Table 24 MQTT in port configuration for IO Link Device Client Status 48 Table 25 MQTT in port configuration for IO Link Device Client Configuration 4...

Page 142: ...PDCT Expert 100 Table 56 Output data of submodule IO Link Wireless Device X I X O PQI PDCT Expert 100 Table 57 Input data of submodule IO Link Wireless Device X I PQI PDCT Expert 101 Table 58 Output d...

Page 143: ...2 Wireless track status WT1 WT3 120 Table 93 Wireless track status WP01 WP16 120 Table 94 Event Qualifier 121 Table 95 IO Link Wireless Master Event Codes 121 Table 96 IO Link Device Event Codes commo...

Page 144: ...checked IP defines special addressing mechanisms see IP address IP addresse Identifies a device or a computer within an IP based network and is defined in the Internet Protocol Version 4 IPv4 as a 32...

Page 145: ...age with safe disconnection PER Packet Error Ratio PLC Programmable Logic Controller Industrial digital computer for the control of manufacturing processes PNIO PROFINET IO PROFINET Communication syst...

Page 146: ...25007068 E mail info hilscher it Support Phone 39 02 25007068 E mail it support hilscher com Japan Hilscher Japan KK Tokyo 160 0022 Phone 81 0 3 5362 0521 E mail info hilscher jp Support Phone 81 0 3...

Reviews: