Configuration
76/146
If the execution was successful, the text
Write ok:
and the result is
displayed in the history. The entries in the history then have the following
structure:
Time - Index:Subindex - Write ok: <Result>
If the execution was not successful, an error message with error codes of
the IO-Link Wireless Master and IO-Link Device is displayed in the history.
The entries in the history then have the following structure:
Time - Index:Subindex - Write failed:
IOLMErrorCode(<error code of the IO-Link master>):
IOLDErrorCode(<error code of the IO-Link Device>)
Delete the history of read and write accesses
To clear the logged history of read and write accesses:
Ø
Click
Clear history
.
ð
The history of read and write accesses is deleted.
8.3.8.7
Master ISDU
The ISDU tab with the option Tigo Master Parameters enabled allows read
and write access to the IO-Link Wireless Master device, by means of
PortId
and
ArgBlockId
message format is used for this.
Figure 34: Display of the ISDU, read/write IO-Link Wireless Master parameters
NFD-3090-PNS-IOLM\W | Hardware, installation and commissioning
DOC201101UM03EN | Revision 3 | English | 2022-02 | Released | Public