MAIN MENU > DOME SETTINGS > PATROLS
PATROLS
PATROL NUM 1
EDIT PATROL
PREVIEW
CLEAR PATH
PATROL_D 30S
BACK EXIT
Figure 3-13
Patrol Configuration Menu
Choose the patrol number.
Steps:
(1)
Move the cursor to
PATROLS NUM
and click
IRIS+
to enter edit mode.
(2)
Click the up and down direction buttons to select the number of the patrol which is to be
configured.
(3)
Click
IRIS+
again to confirm the settings and exit edit mode of this column.
Note:
Up to 8 patrols can be configured.
Edit the patrol.
Steps:
(1)
Move the cursor to
EDIT PATROL
and click
IRIS+
to enter edit mode.
NUM PST DWELL SPD
1 0 6 30
2 0 6 30
3 0 6 30
4 0 6 30
5 0 6 30
6 0 6 30
7 0 6 30
DONE: OPEN QUIT:CLOSE
Figure 3-14
Edit the Patrol
(2)
Click up/down direction buttons to choose the number and locate the preset to be edited.
(3)
Click left/right direction buttons to position the cursor to the column of
PST
(PRESET),
DWELL
and
SPD
(SPEED). You can click the up/down direction buttons to set the value of preset
number, dwell time and patrol speed.
Note:
The presets you set for a patrol should be the ones that have been pre-defined by
users. The dwell time (5-800 seconds selectable) is the time that the speed dome stays on a
certain preset; the patrol speed (level 1-40 selectable) is the scanning speed the speed dome
switching between the presets.
(4)
Follow the above steps to define the other presets for the selected patrol. You can configure