8.2 Setting Sensor Alarms
Purpose
Set up handling method of an external sensor alarm.
Step 1
Enter Alarm Input Settings interface.
Menu > Configuration > Alarm > Alarm Input
Figure 8-5
Alarm Input Settings Interface
Step 2
Select the alarm input.
Step 3
Check the
Enable
checkbox and click
to set its alarm response actions.
Figure 8-6
Set Arming Schedule of Alarm Input
1)
Select
Trigger Channel
tab and select one or more channels which will start to record
or become full-screen monitoring when an external alarm input is triggered.
2)
Select
Arming Schedule
tab to set the channel’s arming schedule.
Select one day of a week and up to eight time periods can be set within each day. Or
you can click the
Copy