DS-PRI120 Security Radar User Manual
UM DS-PRI120 091720NA
44
Figure 6-3 Multipoint Distribution Instance
At least four equally distributed calibration points are required with multi-point calibration.
5.
According to the calibration points, ask the calibration staff to move to a calibration point, and refer to step
4 to step 7 in
One-Point Calibration
to calibrate the calibration point.
6.
When the first calibration point is calibrated completely, have calibration staff move to the next calibration
point after the yellow track disappears, then refer to step 4 to step 7 in
One-Point Calibration
to calibrate
the calibration point. Follow this process to complete all calibration point positioning in turn.
Figure 6-4 Multipoint Calibration Page
7.
After all calibration points is calibrated completely, click
Save
.
You can save the calibration information successfully if there are four to eight calibration
points, otherwise, you cannot save it.