DS-PRI120 Security Radar User Manual
UM DS-PRI120 091720NA
36
Figure 5-10 Multipoint Calibration Radar Page
Every time a calibration point is calibrated completely, the operation staff should not adjust
the PTZ buttons in the live view window (adjustment will change the PTZ position of the
current calibration point and result in an incorrect calibration). You can adjust the PTZ
buttons when calibrating the calibration point.
If you need to delete all calibration points, select the calibration point in the
Information
list,
and click
Delete
to delete the calibration point.
5.
After all calibration points are calibrated completely, click
Save
.
You can save the calibration information successfully if there are three calibration points,
otherwise, you cannot save it.