DS-PRI120 Security Radar User Manual
UM DS-PRI120 091720NA
22
Figure 4-18 Draw a Zone
Adding zones is a batch operation. If you add zones only to one radar, you need to right-click
on the remaining radar detection zones and click
Cancel
.
Zones can overlap. The priority of the effective overlapping zone is: Disabled Zone>Warning
Zone>Early Warning Zone. That is, Early Warning Zone can contain Warning Zone and
Disabled Zone, and Warning Zone can contain Disabled Zone.
You can zoom in/out to adjust the size of the displayed radar area.
Figure 4-19 Overlap Zones
4.
Right-click to complete drawing, and the system will pop up a window. Enter the zone name, and select
Early Warning Zone
,
Warning Zone
, or
Disabled Zone
as the zone type.
•
Early Warning Zone:
The early warning zone will identify target that has potential risks in advance and
trigger alarm, but will not store alarm track. The early warning zone is green.