background image

Keypad User Manual 

12 

 

LED Zone Indicator 

Zone 

Working Status 

Indicator 

Working Status 

Indicator 

Normal 

OFF 

Fault 

Solid Red 

Alarm 

Flicking Red 

Bypass 

Solid Green 

Zone Indicator under 

Engineering 

Mode

 (The corresponding zone indicator light 

will turn orange when operating): 

No. 

Description 

No. 

Description 

Off Hook 

Sending CID Report 

Dialing 

Receiving Confirmation 

Alarm Receiver Off 

Hook 

Control Panel On Hook 

Receiving Handshake 

Alarm Receiver On Hook 

Zone Indicator under

 Status 

Mode 

(The corresponding indicator light will be solid 

red if there is any fault): 

No. 

Description 

No. 

Description 

AC Current Interrupted 

RS-485 Device 

Disconnected 

Low Voltage of Storage 

Battery 

Wired Network Exception 

Movement Prevention of 
Control Panel Turning On 

Wireless Network 

Exception 

Telephone Line 

Disconnected 

Reserved 

 

 

 

Summary of Contents for DS-PK00-LCD series

Page 1: ...Keypad User Manual 1 LCD Keypad User Manual...

Page 2: ...NG TO THE PRODUCT WITH INTERNET ACCESS THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS OUR COMPANY SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESUL...

Page 3: ...he following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to whi...

Page 4: ...nada applicables aux appareils radioexempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit...

Page 5: ...n the required value Do not connect several devices to one power adapter as an adapter overload may cause over heating and can be a fire hazard When the product is installed on a wall or ceiling the d...

Page 6: ...sor not be exposed to the laser beam For working temperature please refer to the specification manual for details To avoid heat accumulation good ventilation is required for a proper operating environ...

Page 7: ...___ 10 Chapter 2 Installation and Wiring ___________________________13 2 1 Wiring Connector Description ______________________________ 13 2 2 Keypad Address Settings __________________________________...

Page 8: ...S PK00 PK00M LCD LED series LCD LED alarm keypad are used for connecting to the security control panel It implements operations on the security control panel through programming and prompts alarm with...

Page 9: ...icator Bar Control Panel Button Description Panic Button Programming Button Search Button Bypass Button Exit Button Stay Arming Button Away Arming Button Indicator Bar Button Description Status Indica...

Page 10: ...ds Fault Prompt 5 Slowly Continuous Beeps Entry Exit Delay 6 Rapidly Continuous Beeps Entry Exit Delay less than 10s 7 Rapid Beeps Zone Alarm The keyboard is not registered 8 Three Long Beeps and Two...

Page 11: ...System Perimeter Armed Orange Arm Working Status Indicator Working Status Indicator Partition Armed Solid Red Partition System Disarmed Solid Green Password Modifying Flicking Green Fob Code Matching...

Page 12: ...ing CID Report 2 Dialing 6 Receiving Confirmation 3 Alarm Receiver Off Hook 7 Control Panel On Hook 4 Receiving Handshake 8 Alarm Receiver On Hook Zone Indicator under Status Mode The corresponding in...

Page 13: ...required for each alarm keypad in the system These addresses cannot be repeated Once exchanging the alarm keypad the address of the new keypad must be the same as the replaced one You should configur...

Page 14: ...ON DIP ON DIP ON DIP 2 3 Keypad Installation Before You Start Make sure that the device in the package is in good condition and all the assembly parts are included Make sure that the wall is strong e...

Page 15: ...th the three buckles on the plate 6 Align the screw holes with the screws on the bottom of both keypad and mounting plate 7 Tighten the screws to fix the keypad on the mounting plate and complete the...

Page 16: ...eration Operator Password Operator Password 0 User No 3digits New Password New Password Clearing Alarm Clearing Under arming status Clearing under disarming status 1 Password 1 Keypad Settings Enablin...

Page 17: ...el Operator Project 10 User No Deleting the Specified Card Operator Project 11 Card No Operator Project 12 Deleting All Card Of a Specified User Operator Project 15 Exiting Card Pairing Mode Schedule...

Reviews: