Alarm Center Test
3.2.14
Partition keypad operation is used to test the communication between security control panel and the alarm
center; see the command below:
{Password} + {*} + {6} + {1} + {#}
One operation generates one test report. It is used to test the communication between the security control panel
and center after installing the system or during the inspection.
Project Mode
3.2.15
Enter the project mode to debug security control panel; see the command below:
{password} + {engineering} + {9} + {0} + {n} + {#}
Long press {Project}
/ {State} or {*} {
#
} key to exit the project mode after debugging.
When the evaluation of n is 1 or 2, the test dialing center is in dialing status.
Enabling/Disabling Key Tone
3.2.16
For keypad tone status switch, see the command below:
{*} + {5} + {1} + {#}
Connecting Wireless Device and Control Panel
3.2.17
If the control panel and keypad are both working properly, enter the following code with the keypad to enter the
connecting mode.
[Password] + [*] + [91] + [No.] + [#]
Press any key to exit the mode after connecting succeeded.
The range of No. is 01~32, which indicates 32 wireless devices.
Deleting Connected Wireless Device
3.2.18
Enter the following code with the keypad to delete the device associated to the wireless user No..
[Password] + [*] + [90] + [No.] + [#]