Video Security Control Panel User Manual
--142-
-
uploading mode in
Remote Settings
->
Uploading Mode Settings
Q: How to configure the communication way of video security control panel and alarm center group?
A:
1.
Center uploading mode supports at most 6 center groups, each center group divides in main channel
and 3 backup channels;
2.
If the center group is enabled. Enable the center group before the use.
3.
For example: The control panel needs to upload report to network alarm center 1 and dialing
alarm center1 and network alarm center 1 needs to upload report to network alarm center 2
when it fails to upload it. The configurations are as follows:
1)
Enable Group1 and Group2;
2)
In the uploading mode configuration list, select N1 in center group 1 main channel, select N2
in backup channel 1, select T1 in Center group2 main channel.
3)
Click
Apply
.
If the client is not opened, the user can realize communication with alarm center by programming with
keypad. For detailed operations please refer to program command 611~634.
Q: Why cannot it upload report and control after WIFI is enabled?
A:
The follow situations may lead to WIWI connection failure:
1)
No SIM Card or poor contact;
2)
3G module antenna is not normally connected or with poor signal;
3)
WIFI parameter setting is incorrect;
4)
SIM Card has no enough tariffs.