HIKVISION DS-19S08N-04F/K Series User Manual Download Page 133

Video Security Control Panel User Manual 

 

 

 

--133-

 

 

Status 

You can view status of the partition, zone, trigger, siren ,and storage battery in this section. 

Summary of Contents for DS-19S08N-04F/K Series

Page 1: ...Video Security Control Panel User Manual 1 Video Security Control Panel User Manual UD 6L0206D1028A01...

Page 2: ...rademarks and logos are the properties of Hikvision in various jurisdictions Other trademarks and logos mentioned below are the properties of their respective owners Legal Disclaimer TO THE MAXIMUM EX...

Page 3: ...Control Panel User Manual 3 NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW THE LATER PREVAILS...

Page 4: ...erence that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore with the applicable harmonized Eur...

Page 5: ...be less than the required value Do not connect several devices to one power adapter as an adapter overload may cause over heating and can be a fire hazard When the product is installed on a wall or ce...

Page 6: ...of the sensor not be exposed to the laser beam For working temperature please refer to the specification manual for details To avoid heat accumulation good ventilation is required for a proper operat...

Page 7: ...__________________________________________________ 22 2 3 2 Keypad Address _______________________________________________________ 24 2 3 3 Factory Settings ___________________________________________...

Page 8: ...________ 57 3 1 28 Partition Fault Prompt Sound Settings______________________________________ 58 3 1 29 DHCP Settings_________________________________________________________ 58 3 1 30 Delay Zone Tim...

Page 9: ...______________ 83 3 2 24 Current Fault Tone Disabling _____________________________________________ 83 3 2 25 Test Report Manually Triggering __________________________________________ 83 3 2 26 Keypa...

Page 10: ...l User Manual 10 Appendix2 CID Report______________________________________________148 Appendix3 LED Keypad Prompt Sound_________________________________150 Appendix4 Conversion Table_________________...

Page 11: ...nts communities etc It can be used cooperatively with the video surveillance and access control partition through the software operation 1 2 Feature Signal Input Output 8 zones alarm input 4 ch networ...

Page 12: ...ernal alarm keypads are accessible External storage battery for power supply Various Applications Equipped with LED LCD keypad Scheduled arming disarming function Tamper proof alarm and movement preve...

Page 13: ...Video Security Control Panel User Manual 13 Chapter 2 Installation and Wiring 2 1 Main Board Overview DS 19S08 04F Kx Gx...

Page 14: ...Video Security Control Panel User Manual 14 DS 19S08N 04F Kx Gx...

Page 15: ...ion 1 Keypad Board Interface 11 Reset Button Switch 2 SATA HDD Interface 12 Tampering Prevention 3 HDD Power Interface 13 Movement Prevention Switch 4 Alarm Input Interface 14 SIM Card Slot 5 Alarm Ou...

Page 16: ...interfaces of the control panel are show as follows Take the model of DS 19S08 04F Kx Gx as an example The wiring of sensor is shown as follows 8 2K NC C Z G Peripheral Security Detector Alarm Host N...

Page 17: ...2 2 Take the model of DS 19S08 04F Kx Gx as an example the alarm output interfaces of the video security control panel are show as follows The resistance of 2 2K or 3 3K supports tamper proof and non...

Page 18: ...utput is shown as follows External Device NO NC COM DC12V Breaker External DC Load External Device NO NC COM DC12V Breaker AC220V External AC Load Relay The DC current supplied by the control panel ca...

Page 19: ...l 19 Wiring Keypad 2 2 3 The keypad wiring is shown as follows Take the model of DS 19S08 04F Kx Gx as an example Wiring Video Audio Input 2 2 4 The video audio wiring is shown as follows Take the mod...

Page 20: ...Video Security Control Panel User Manual 20 Wiring Video Audio Output 2 2 5 Take the model of DS 19S08 04F Kx Gx as an example...

Page 21: ...Video Security Control Panel User Manual 21...

Page 22: ...it being powered on If the registration is succeeded the working status indicator will turn green LED Alarm Keypad Arming Disarming Status Working Status Indicator Status Working Status Indicator Stat...

Page 23: ...ndicator Status Working Status Indicator Status In Programming Green Flickering Main Operator Password Editing Green Flickering Parameters Initialization Green Flickering Re searching Green Flickering...

Page 24: ...sly Light Partition Not Enabled Extinguishing LCD Partition Keypad Working Status Working Status Indicator Status Working Status Indicator Status In Programming Green Flickering Parameters Initializat...

Page 25: ...e for reservation and should be in the status of OFF Factory Settings 2 3 4 If you power on the system before zone connection a 2 2k Ohm resistance is required for bridge connection between each zone...

Page 26: ...ase refer to CID Report Zone Zone 1to8 Real time zone Urgent Soft zone Buzzing prompt sound Test Testing Report Interval N A Timing Entering Delay Duration 10 sec Exiting Delay Duration 30 sec Belling...

Page 27: ...tware is used for detecting the online device activating the device and resetting the password Get the SADP software from the supplied disk or the official website and install the SADP according to th...

Page 28: ...the popup window If activation failed please make sure that the password meets the requirement and then try again 5 Change the device IP address to the same subnet with your computer by either modify...

Page 29: ...Video Security Control Panel User Manual 29 2 Click the Device Management icon to enter the Device Management interface as shown in the figure below...

Page 30: ...create a strong password of your own choosing using a minimum of 8 characters including upper case letters lower case letters numbers and special characters in order to increase the security of your p...

Page 31: ...User Manual 31 8 Change the device IP address to the same subnet with your computer by either modifying the IP address manually or checking the checkbox of Enable DHCP 9 Input the password to activate...

Page 32: ...shown below 012345 0 1 2 1 Installer Password 012345 2 Command Key 0 The command for exiting programming mode is Installer Password Settings 3 1 1 The password of installer is used for accessing prog...

Page 33: ...No Permission No Permission 1 Arming No Arming Report Unavailable Bypass 2 Disarming No Disarming Report Unavailable Bypass 3 Arming Disarming No Arming Disarming Report Unavailable Bypass 4 Arming Ar...

Page 34: ...eters Programming Address 201 208 216 For 8 zone video security control panel the zone parameters programming address is 201 208 For 16 zone video security control panel the zone parameters programmin...

Page 35: ...ved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 5 Liked Alarm Output Command Command Description Command Command Description 0 Non linked Alarm Output 1 Linked Alarm Output 6 Bypass Group Command Comm...

Page 36: ...ut 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 Reserved 7 Reserved 8 Reserved 9 Reserved 0 Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 10 Tampering Prevention Linked Siren Output...

Page 37: ...ing Address 467 2 Zone No 3 Adding Deleting Trigger Command Command Description Command Command Description 0 Delete 1 Add 4 Trigger No 5 End the command After successfully operating once you can cont...

Page 38: ...Device 01 System 5 Event No The device event command is shown below Command Command Description Command Command Description 00 None 03 Reserved 01 AC Power Down 04 Wired Network Exception 02 Low Batte...

Page 39: ...e command The maximum duration of triggering is 99 minutes and 59 seconds The default duration is 30 seconds After operating once you can continuously configure with the command of Project Trigger No...

Page 40: ...ontrol panel IP configuration please refer to the command below 473 192 000 000 064 1 2 3 5 4 6 1 Control Panel IP Settings Programming Address 473 2 Unit 1 3 Unit 2 4 Unit 3 5 Unit 4 6 End the comman...

Page 41: ...rt Tens Digit 6 Port Digit 7 End the command Corresponding port number must be 5 bytes When the place is not sufficient fill it up with 0 For example When the port number is 6000 the programming comma...

Page 42: ...r IP Settings 3 1 13 The programming commands of uploading center IP setting are as below 485 000 000 000 000 1 2 4 6 3 5 1 The programming command address of uploading center IP setting are 485 488 4...

Page 43: ...89 Programming Address of Network Center 2 Port Setting 492 Programming Address of WIFI Center 1 Port Setting 495 Programming Address of WIFI Center 2 Port Setting 2 Port Number 3 End the command Cent...

Page 44: ...ters setting are as below 499 0 0 0 1 2 3 4 5 1 The programming command address of printer parameter setting is 499 2 Enable disable the printer Command Description Command Description 0 Disable the P...

Page 45: ...e emergency alarm Command Description Command Description 0 Disable Emergency Alarm 1 Enable Emergency Alarm 4 Enable disable duress alarm Command Description Command Description 0 Disable Control Pan...

Page 46: ...programming information are as below 502 0 0 0 0 0 0 0 1 2 4 6 3 5 7 9 8 1 The programming command address of print setting of operation programming information is 502 2 Arming 3 Disarming 4 Canceling...

Page 47: ...commands of print setting of device recovering information are as below 504 0 0 0 0 0 0 0 1 2 4 6 3 5 7 8 9 1 The programming command address of print setting of device recovering information is 504...

Page 48: ...iled Event Type The global event types are shown below Command Description Command Description Command Description 00 Null 01 Control Panel Tampering Alarm 02 Global Keypad Emergency Alarm 03 Ac Disco...

Page 49: ...n Setting 3 1 23 The programming commands of emergency alarm linkage siren setting are as below 510 00 0 1 2 3 4 1 The programming command address of emergency alarm linkage setting is 510 2 Partition...

Page 50: ...o validate the communication of control panel and alarm center The detailed operation is show as follows 513 0 1 5 1 2 3 5 4 1 Testing Report Programming Address 513 2 Enable Disable the testing repor...

Page 51: ...9 7D 5 24H 5 End the command Partition Settings 3 1 26 Partition Start up Settings The programming command of the partition start up configuration is shown below 531 1 1 1 4 2 3 1 The programming of p...

Page 52: ...ion 0 Delete 1 Add 4 The user No 5 End the command Added Separately for instance to add an user with the No of 160 to the No 8 partition the command should be 538 2 1 160 Added Deleted Continually onl...

Page 53: ...ion Command Command Description 0 Delete 1 Add 4 Zone No 5 End the command There are three mode to add delete zone for the partition adding deleting separately Adding Deleting continually and adding d...

Page 54: ...tings To configure the system time and control panel duress report please see the command below 531 5 1 3 2 0 1 2 4 6 3 5 7 1 System Time and Control Panel Duress Report Programming Address 531 2 Clas...

Page 55: ...n 2 5min 3 10min 4 15min 5 30min 6 Enable Disable Control Panel duress Report Command Command Description Command Command Description 0 Disable 1 Enable 7 End the command The 24 hour non voiced zone d...

Page 56: ...ion Settings To configure the permission of key user please see the command below 531 7 1 1 1 1 1 2 4 6 3 5 7 1 System key user permission programming address 531 2 System key user classification opti...

Page 57: ...on 7 Network Exception 8 Wireless Network Exception Command Command Description Command Command Description 0 Disable 1 Enable 9 End the command If the fault detection is disabled the control panel wi...

Page 58: ...prompt sound please see the command below 568 01 01 1 1 1 1 1 1 1 1 2 4 6 3 5 7 8 9 10 11 1 Partition fault display configuration Programming address 568 2 The Tens Digit of the Partition System No 3...

Page 59: ...ttings is 610 2 The hundreds s digit of the zone No 3 The tens digit of the zone No 4 The units digit of the zone No 5 The thousands digit of the delay exiting time 6 The hundreds s digit of the delay...

Page 60: ...mming Address 619 Center Group 3 Enabling Programming Address 623 Center Group 4 Enabling Programming Address 627 Center Group 5 Enabling Programming Address 631 Center Group 6 Enabling Programming Ad...

Page 61: ...ogramming Address 2 Main Channel 3 Backup Channel 1 4 Backup Channel 2 5 Backup Channel 3 2 5 The channel can be selected as follows Command Command Description Command Command Description 0 OFF 1 T1...

Page 62: ...larm report Programming address 633 Center group 6 zone alarm report Programming address 2 Delete Add 3 Zone No 4 End the command The operation of adding deleting is just for current center group send...

Page 63: ...ss 2 Soft zone Report 3 System Status Report 4 Alarm Clearing Report 5 Testing Report 6 Arming Report 7 Disarming Report 8 Control Panel Duress Report 9 Alarm Recovery Report 10 Bypass Report 11 Bypas...

Page 64: ...ypass Recovery Report 4 13 set the value as 1 to send the report Set the value as 0 not to send the report Command Command Description Command Command Description 0 Not Sending 1 Sending 14 End the co...

Page 65: ...ngs Command Address 682 2 It indicates the white list number 01 08 indicate white list No 1 No 8 3 The Disarming Permission of Partition 1 4 The Disarming Permission of Partition 2 5 The Disarming Per...

Page 66: ...ission of Partition 6 9 The Alarm Clearing Permission of Partition 7 10 The Alarm Clearing Permission of Partition 8 3 10 It indicates to enable disable the permission of Partition Alarm Clearing Comm...

Page 67: ...nfigure the telephone number please refer to the command below 685 01 1 E0 0 1 4 5 2 3 1 Telephone Number Command Address 685 2 It indicates the white list number 01 08 indicate white list No 1 No 8 3...

Page 68: ...Command Description 0 Not Sending 1 Sending 4 zone No Hundreds Digit 5 zone No Tens Digit 6 zone No Digit When the zone No has no hundreds digit 4 can be omitted Example When you want to send report o...

Page 69: ...cription 0 Disable 1 Enable 5 End the command Weekly Schedule Time Parameter Settings To configure the time parameters of the weekly schedule please refer to the command below 691 01 1 1 0 0 0 0 0 0 0...

Page 70: ...u set the start and end time as non zero the start time must be 5min greater than the end time of the previous time bucket When you set the start and end time as non zero if the time bucket is overlap...

Page 71: ...4 Thursday 5 End the command Copy Weekly Schedule of Partition To copy the settings of partition m to partition n please refer to the command below 693 01 02 1 2 3 4 1 Copy Weekly Schedule of Partiti...

Page 72: ...Description Command Command Description 0 Disable 1 Enable 5 12 It indicates the start date and end date Start Date 5 6 7 8 The former is the month value range 1 12 while the latter is the day value...

Page 73: ...the start time and end time during the time bucket of 3 Start Time 4 5 6 7 End Time 8 9 10 11 When you set the start and end time as 00 00 and 00 00 all the settings from the present time bucket to t...

Page 74: ...ling Trigger Schedule Command Address 697 2 It indicates to enable disable the trigger schedule Command Command Description Command Command Description 0 Enable 1 Disable 3 End the command Trigger Sch...

Page 75: ...End Time 7 8 9 10 When you set the start and end time as 00 00 and 00 00 all the settings from the present time bucket to the maximum time bucket will be cleared When you set the start and end time a...

Page 76: ...1 1 1 1 2 4 6 3 5 7 1 Wireless User Permission Settings Command Address 701 732 701 732 indicate wireless users No 1 No 32 2 Arming 3 Arming Report 4 Disarming 5 Disarming Report 6 Alarm Clearing 2 6...

Page 77: ...ault password for the installer 012345 Security control panel Arming and Disarm 3 2 2 The operation of security control panel arming and disarming is the same Take the password 1234 as an example and...

Page 78: ...one will be blocked see the command below User password bypass zone Number For continuous bypass recovery see the command below 1234 1 Bypass 2 Bypass Bypass 8 15 Seconds Continuous operation of multi...

Page 79: ...e command below Password 8 5 n For disabling alarm output of the alarm keypad see the command below Password 8 6 n The security control panel supports 16 channels of alarm outputs the N valuation shou...

Page 80: ...ssword The password will be changed by the above four steps The User Number must be expressed into three bytes such as 002 Entering Partition System 3 2 12 See the command below to enter the partition...

Page 81: ...n Long press Project State or key to exit the project mode after debugging When the evaluation of n is 1 or 2 the test dialing center is in dialing status Enabling Disabling Key Tone 3 2 16 For keypa...

Page 82: ...low Installer Password 8 1 Clearing Weekly Schedule Installer Password 8 2 Clearing Preferential Schedule Installer Password 8 3 LCD Backlight Control 3 2 21 For LCD backlight control see the command...

Page 83: ...he test report will not be cleared and will remain the value before recovery till the recovery processes being completed Current Fault Tone Disabling 3 2 25 To disable the current fault tone see the c...

Page 84: ...are included 4 1 Installing the iVMS 4200 Insert the installation media of iVMS 4200 into the appropriate computer Perform the following steps to install the iVMS 4200 client software 1 Double click...

Page 85: ...allation 3 On the next panel you are prompted to select the function module to install Set installation directory where the client software is to be installed You can either accept the default directo...

Page 86: ...r Manual 86 software 2 Read the pre install information and click Install to begin the installation 3 A panel indicating progress of the installation is displayed A percentage completion bar is update...

Page 87: ...r Manual 87 4 Select the setup type according to your need You can check the checkbox of Create Desktop for Client to create a shortcut icon on the desktop for the client software 5 Read the post inst...

Page 88: ...ord 3 Optionally check the checkbox of Enable Auto login to log in the software automatically 4 Click Register Then you can log in the software as the super user A user name cannot contain any of the...

Page 89: ...put the required information Nickname Edit a name for the device as you want Address Input the device s IP address or domain name Port Input the device port number The default value is 8000 User Name...

Page 90: ...nd password 4 Click Modify to save the changes Delete a Device Select device from the list click Modify Delete and then you can modify delete the information of the selected device 4 4 Remote Settings...

Page 91: ...Security Control Panel User Manual 91 System Information Settings Purpose In this section you can configure the system parameters such as time log user security system maintenance and so on for the d...

Page 92: ...ol Panel User Manual 92 Timing Settings Before You Start Before you start configuring the security control panel you need to do timing for the device first Enter Remote Settings System Time to get the...

Page 93: ...User Manual 93 User Settings Purpose You can add edit or delete the network operator and keypad operator in this section Network User Add a Network User Steps 1 Enter the user configuration interface...

Page 94: ...k to enter the interface of adding a network user 3 Enter the corresponding user information including the user type user name password IP address and MAC address 4 Select the permission of the user 5...

Page 95: ...rresponding user information including the user type user name password IP address and MAC address 3 Edit the permission of the user 4 Click OK to finish the settings Delete a user Steps 1 Select a us...

Page 96: ...elected 3 Enter the name of the keypad operator 4 Enter the password of the operator 5 Click the dropdown menu to select the user permission 6 Click Apply to save the settings Camera Settings You can...

Page 97: ...mation such as IP address or domain name port No name password and so on 5 Click Save to save the settings 6 You can also click Modify or Remove to edit or delete the camera Network Settings Purpose Y...

Page 98: ...clients to acquire the stream at the same time by requesting a copy from the multicast group address Before utilizing this function you have to enable the Multicast function of your router and configu...

Page 99: ...er HiDDNS PeanutHull and DynDNS DynDNS Steps 1 Enter Server Address of DynDNS e g members dyndns org 2 Enter the User Name and Password registered on the DynDNS website 3 Enter the domain name obtaine...

Page 100: ...sk and gateway and preferred DNS from the ISP PeanutHull Steps 1 Enter the User Name and Password registered on the NO IP website 2 Click Apply to save the settings Uploading Mode Settings Purpose You...

Page 101: ...combined to send the alarm report 5 Check the checkbox to select the type of non Zone alarm report 6 Click each dropdown menu to configure the uploading channel 7 Click Apply to save the settings The...

Page 102: ...mmunicating with the alarm receiving center 6 Click the dropdown menu to select the protocol type 7 Enter the username which is applying for displaying in the alarm receiving center The length of the...

Page 103: ...ect a center type 6 Enter the center name and phone number The maximum length of center name is 32 characters The phone number should be 31 characters and the input mode is NO Dwell Time EXT NO For ex...

Page 104: ...epending on the models of the control panel Wireless Center Parameter Settings Steps 1 Enter the wireless center parameter settings page Remote Settings Network Wireless Center 2 Click the dropdown me...

Page 105: ...ct the protocol type 7 Click Apply to save the settings Advanced Network Parameters Settings Steps 1 Enter the advanced network configuration page Remote Settings Network Advanced 2 Enter the correspo...

Page 106: ...x to enable the configuration 4 Enter the phone number of the whitelist into the SIM Card Number text box 5 Select the identical message time interval which represents the interval of sending message...

Page 107: ...select a partition 3 Click the Linkage button to add required Zone keypad or keypad user to the partition 4 Check the check box of Enable Partition or Public Partition to enable functions of the parti...

Page 108: ...report Arming Partition in Key switch Zone Support the key Zone to arm the current partition Send Report when Arming Key switch Zone Enable uploading report when the key Zone arms the current partiti...

Page 109: ...Security Control Panel User Manual 109 2 Click the Partition dropdown menu to select a partition 3 In the Alarm Input list select an alarm input channel and click the icon to enter Zone configuration...

Page 110: ...Type Select the type of Zone in the partition Sensitivity Select the response time of the Zone 5 Select the linked siren and linked trigger 6 Click Copy to to copy all these settings to other Zones 7...

Page 111: ...g triggered 4 Click the dropdown menu to enable disable the event linked trigger 5 Select the detailed operation after the alarm being triggered on the sub system event panel 6 Select the global event...

Page 112: ...Select the detailed operation after the alarm being triggered on the sub system event panel 6 Select the global event of alarm triggering 7 Click Apply to save the settings Trigger Output Schedule Set...

Page 113: ...the Zone configuration page 3 Check the Enable checkbox to enable the configuration 4 Click the icon click and drag the mouse on the time bar the time bar is divided into 24 segments which represent 2...

Page 114: ...ng Schedule Settings Steps 1 Enter the arming disarming schedule configuration interface Remote Settings Alarm Partition Scheduling Arming Disarming 2 Select a partition needs to be configured 3 Check...

Page 115: ...chedule Delete Schedule Click the drawn color bar and click the icon to delete the color bar Clear Schedule Click the icon to clear the drawn the schedule Copy Schedule Click the drawn color bar and c...

Page 116: ...eferential schedule configuration interface Remote Settings Alarm Preferential Schedule Arming Disarming 2 Click the drop down menu to select the time duration 3 Click the icon to enter the preferenti...

Page 117: ...ule 6 Click Save to save the settings and click Cancel to exit the page 7 Click Copy to to copy all these settings to other Zones 8 Click Apply to save the settings Module Information Purpose You can...

Page 118: ...Click and select the external device from the module type dropdown menu 3 View the information about the selected device Alarm Capture Settings Steps 1 Enter the alarm capture configuration interface...

Page 119: ...cture and the next picture Default 2s 4 Select the resolution of the captured picture 5 Set the number of pictures needs to be captured before after the alarm being triggered 6 Click Apply to save the...

Page 120: ...function of uploading alarm recovery report 5 Select the linked siren on the Linked Siren panel 6 Select the linked trigger on the Linked Trigger panel 7 Click Copy to to copy all these settings to o...

Page 121: ...ge 3 Check the Enable checkbox to enable the configuration 4 Enter the serial number of the remote control The number of 000000000 indicates to delete the remote control 5 Select the partition NO to b...

Page 122: ...and property of the disk Remote Settings Storage General 2 If the status of the HDD is Uninitialized check the corresponding checkbox to select the disk and click to start initializing the disk When t...

Page 123: ...y interface Remote Settings Storage File 2 Enter the search criteria including camera name property start time and end time 3 Click Search to get the file list Image Settings Video Audio Settings Step...

Page 124: ...deo audio composite stream Bitrate Type Select the bitrate type to constant or variable Resolution Select the resolution of the video output Frame Rate The frame rate is to describe the frequency at w...

Page 125: ...he camera name in the text field of Camera Name 4 Select from the drop down list to set the time format date format and display mode 5 Check the checkbox in front of textbox to enable the on screen di...

Page 126: ...ction 2 Select a camera needs to be configured 3 Check the checkbox of the Enable Motion Detection to enable this function 4 You can check the Enable Motion Dynamic Analysis checkbox if you want the d...

Page 127: ...ve the settings Tampering Alarm Settings Purpose You can configure the camera to trigger the alarm actions when the lens is covered Steps 1 Enter the video tampering Settings interface Remote Settings...

Page 128: ...area Refer to Step 5 in Section5 2 26 1 Motion Detection Settings 5 Set the arming schedule for tampering 6 Check the Audible Warning checkbox to enable audible warning for the detection 7 Click Apply...

Page 129: ...e Enable Video Loss Detection checkbox to enable the video loss detection 4 Check the check box to link the camera with alarm output 5 Set the schedule for the video loss detection 6 Check the Audible...

Page 130: ...1 Enter the Exception Settings interface Remote Settings Events Exception 2 Select a camera needs to be configured 3 Select an exception type 4 Check the checkbox to set the actions taken for the Exc...

Page 131: ...e 5 Click the icon to set the record schedule 6 Click Edit to enter the Templates Management interface Select the template to be set and you can edit the template name 7 Set the time schedule for the...

Page 132: ...d time post record time video expired time and audio recording 11 Click Copy to to copy all these settings to other Zones Click Apply to save the settings Operation You can configure the partition zon...

Page 133: ...Video Security Control Panel User Manual 133 Status You can view status of the partition zone trigger siren and storage battery in this section...

Page 134: ...Video Security Control Panel User Manual 134...

Page 135: ...system automatically displays the interface of first priority 3 The switch between interfaces of same priority there are two ways to switch sensor alarm display interface to sensor off line display in...

Page 136: ...und of error and corresponding OSD notices after each program command is over When 5 alert sound of error is heard and the screen displays Operation Failed there is error in program command setting an...

Page 137: ...hook 4 Receive the Hand shack Sound 8 Alarm Connector On hook LED keypad Channel indicator under Status Mode No Description No Description 1 AC Power off 5 Keypad Off line 2 Battery Low Voltage 6 Net...

Page 138: ...ton and number button 0 5 Q How to set LED keypad address A Set LED keypad address with the DIP address of keypad DIP Add DIP Add DIP Add DIP Add 2 1 3 4 5 ON DIP 0 2 1 3 4 5 ON DIP 1 2 1 3 4 5 ON DIP...

Page 139: ...for setting duress code A 1 The description of duress code is as follow Input duress code when the user is under duress it will work as if the user inputs valid password but the system will auto uplo...

Page 140: ...ization password of main operator is 1234 the permission is arm disarm There is arm disarm report and bypass is permitted Please refer to FAQ of hardware initialization for more information about hard...

Page 141: ...ompt Please check if the device IP Address and Port No are correct The device default IP Address is 192 0 0 64 and the Port No is 8000 Please check if the user name and password to log in the control...

Page 142: ...rt to network alarm center 2 when it fails to upload it The configurations are as follows 1 Enable Group1 and Group2 2 In the uploading mode configuration list select N1 in center group 1 main channel...

Page 143: ...Support Tamper proof and Movement Prevention Function Partition System 8 Partition Systems 1 Public Partition System Scheduled Arming Disarming 8 Time Periods Each Day Detector Tamper proof Alarm Supp...

Page 144: ...Record Motion Detection Record Playback Mode Instant Playback Normal Playback Event Playback HDD Information Build in 500G 2 5 HDD SATA Interface Wireless Network Parameters Wireless Network Standard...

Page 145: ...Security Control Panel User Manual 145 Model DS 19S08N 04F Kx DS 19S08N 04F KxGx Working Temperature 10 C 55 C 14 F 131 F Working Humidity 10 90 Mounting Wall mounted Dimensions 200 247 35mm Weight 0...

Page 146: ...ition System Detector Tamper proof Alarm Support Supported Remote Controls 32 Unobstructed Effective Range of 100m SMS Alarm Data push N A Support SMS Arming disarming Data push N A Support Media Para...

Page 147: ...ck HDD Information 500G 2 5 HDD SATA Interface Wireless Network Parameters Wireless Network Standard N A GLT 4G TDD LTE GLF 4G FDD LTE GW 3G WCDMA GE 3G EVDO UIM Card Slot 1 SMA Antenna Interface 1 Ne...

Page 148: ...m 3134 Delay Zone Alarm Recovery 1137 Tampering Alarm 3137 Tampering Alarm Recovery 1301 AC Power Down 3301 AC Power Down Recovery 1302 Low Battery 3302 Low Battery Recovery 1305 control panel Restori...

Page 149: ...ecovery 1940 Motion Detection Enabling 3940 Motion Detection Disabling 1941 Tampering Alarm Enabling 3941 Tampering Alarm Disabling 1942 Video Loss Alarm Enabling 3942 Video Loss Alarm Disabling 1943...

Page 150: ...ceeded 3 5 Sound Incorrectly answered report uploading failed in 60s 4 Last for 2s Error Prompt 5 Intermittent Slow Sound Continuously Enter Exit Delay 6 Intermittent Rapid Sound Continuously Enter Ex...

Page 151: ...User Name 2 3 6 0 0 0 0 23 Password 0 User Name 2 4 6 0 0 0 0 24 Password 0 User Name 2 5 6 0 0 0 0 25 Password 0 User Name 2 6 6 0 0 0 0 26 Password 0 User Name 2 7 6 0 0 0 0 27 Password 0 User Name...

Page 152: ...er Name 7 3 6 0 0 0 0 73 Password 0 User Name 7 4 6 0 0 0 0 74 Password 0 User Name 7 5 6 0 0 0 0 75 Password 0 User Name 7 6 6 0 0 0 0 76 Password 0 User Name 7 7 6 0 0 0 0 77 Password 0 User Name 7...

Page 153: ...Name 2 3 6 0 0 0 0 123 Password 1 User Name 2 4 6 0 0 0 0 124 Password 1 User Name 2 5 6 0 0 0 0 125 Password 1 User Name 2 6 6 0 0 0 0 126 Password 1 User Name 2 7 6 0 0 0 0 127 Password 1 User Name...

Page 154: ...Name 7 3 6 0 0 0 0 173 Password 1 User Name 7 4 6 0 0 0 0 174 Password 1 User Name 7 5 6 0 0 0 0 175 Password 1 User Name 7 6 6 0 0 0 0 176 Password 1 User Name 7 7 6 0 0 0 0 177 Password 1 User Name...

Page 155: ...n 2 1 1 1 2 5 1 0 Region11 Parameters Configuration 2 0 1 2 2 5 0 1 Region12 Parameters Configuration 2 1 1 3 2 5 0 1 Region13 Parameters Configuration 2 1 1 4 2 5 0 1 Region14 Parameters Configuratio...

Page 156: ...e Settings 9 2 0 0 0 0 7 6 Gateway Settings 4 7 5 4 5 5 0 0 0 0 0 0 5 5 0 0 2 2 5 2 5 Subnet Mask Settings 0 0 0 0 0 0 0 8 5 4 0 0 0 0 0 0 0 0 0 0 0 0 8 6 4 0 0 0 0 0 8 7 4 2 0 0 0 0 0 0 Network Cente...

Page 157: ...uration Programming Address 0 1 Device Information Printing Configuration 5 0 2 Operation Programming Information Printing Configuration 5 0 0 0 0 0 Alarm Information Printing Configuration 5 0 0 0 0...

Page 158: ...ion Center Group 1 Uploading Mode Configuration Center Group 1 Region Alarm Report Configuration 1 8 6 1 5 6 0 1 1 1 1 1 1 1 1 7 6 1 1 1 0 0 0 0 1 6 6 0 0 0 0 Center Group 2 Non region Alarm Report Co...

Page 159: ...1 1 1 2 9 6 1 1 1 0 0 0 0 2 8 6 0 0 0 0 Center Group 5 Non region Alarm Report Configuration Center Group 5 Enabling Configuration Center Group 5 Uploading Mode Configuration Center Group 5 Region Al...

Page 160: ...First Choice for Security Professionals...

Reviews: