Video Security Control Panel User Manual
--73--
{7}
Partition 5
{8}
Partition 6
{9}
Partition 7
{10}
Partition 8
{3}~{10
} It indicates to enable/disable prior schedule of Partition No.1~No.8.
Command
Command Description
Command
Command Description
0
Disable
1
Enable
{11}
End the command.
Prior Schedule Time Parameter Settings
To configure the time parameters of the prior schedule, please refer to the command below.
696 00 0 0 0 0 0 0 0 0 0 E #
1
2
4
6
3
5
8
7
9 10 11 12 13
{1}
Prior Schedule Time Parameter Settings Command Address: 696.
{2}
It indicates the prior schedule number. 01~30 indicate prior schedule No.1~No.30.
{3}
It presents the time bucket composed by
{4}~{11}
. The value range is 1~8.
{4}~{11}
It indicates the start time and end time during the time bucket of
{3}
.
Start Time:
{4}{5}:{6}{7}
End Time:
{8}{9}:{10}{11}
When you set the start and end time as 00:00 and 00:00, all the settings from the present time bucket
to the maximum time bucket will be cleared.
When you set the start and end time as non-zero, the previous time bucket must be non-zero.
When you set the start and end time as non-zero, only Arming in
{12}
can be set.
When you set the start and end time as non-zero, end time must be greater than start time in every
time bucket.
When you set the start and end time as non-zero, the start time must be 5min greater than the end
time of the previous time bucket.
When you set the start and end time as non-zero, if the time bucket is overlapped with the latter ones,
or the difference between them is less than 5min, all the settings of the latter ones will be cleared.
{12}
Three types of Arming/Disarming.