
Control Panel User Manual
83
3.2.17
Alarm Center Test
Partition keypad operation is used to test the communication between control
panel and the alarm center; see the command below:
{password} + {*} + {6} + {1} + {#}
One operation generates one test report. It is used to test the communication
between the control panel and center after installing the system or during the
inspection.
3.2.18
Project Mode
Enter the project mode to debug alarm control panel; see the command
below:
{password} + {project} + {9} + {0} + {n} + {#}
Long press {Project}
/ {State} or {*} {
#
} key to exit the project mode after
debugging.
When the evaluation of n is 1 or 2, the handset 1 and 2 are in dialing status.
When the evaluation of n is 3 or 4, the network center1 and 2 are in uploading
status.
When the evaluation of n is 5 or 6, the GPRS center is 1 and 2 are in uploading
status.
3.2.19
Enabling/Disabling Key Tone
For keypad tone status switch, see the command below:
{*} + {5} + {1} + {#}
3.2.20
LCD Backlight Control
For LCD backlight control; see the command below
:
{*} + {5} + {2} + {n} + {n} + {n} + {#}
{n}{n}{n}refers to the light duration in seconds, and 999 means the LCD is
always light The default duration is 900 seconds, and the parameters will be
restored after reboot.
Summary of Contents for DS-19A08-F/Kx
Page 1: ...Control Panel User Manual 1 UD 6L0206D1044A02 Network Security Control Panel User Manual...
Page 13: ...Control Panel User Manual 13 Chapter 2 Installation and Wiring 2 1 Main Board Overview...
Page 100: ...Control Panel User Manual 100 2 Click to enter the interface of adding a network user...
Page 130: ...Control Panel User Manual 130...
Page 156: ...Control Panel User Manual 156...