510 00 0 #
1
2
3 4
{1}
The programming command address of emergency alarm linkage
setting is: 510;
{2}
Partition Number, 00 indicate the global keypad, 01~08 indicate
partitions No.1~No.8;
{3}
Whether to link the siren or not;
Command
Description
Command
Description
0
Not link the Siren
1
Link the Siren
{4}
End the command.
3.1.22
Control Panel Tampering Alarm Configuration
The programming command of control panel tampering alarm settings is
shown below:
511 0 #
1
2
3
{1}
The programming command address of control panel tampering
alarm is: 511;
{2}
whether to link the siren or not;
Command
Description
Command
Description
0
Not link the Siren
1
Link the Siren
{3}
End the command.
3.1.23
Testing Report Configuration
The testing report is used to validate the communication of control panel and