CHAPTER 3
Menu System
22
SolaWash 19 LED User Manual
Menu System Options
The following sections describe and give examples for selecting and/or setting available fixture
configuration options.
Address Menu
Address is the top level menu selection used to set the fixture’s DMX start channel. You can
address the fixture before applying power in the battery mode or in normal mode after you power
up the fixture.
A SolaWash 19 LED fixture requires a 21-channel range when set to run Standard protocol. The
last valid Start channel for standard user mode is 492 (512–21+1).
Other protocol options are available and require a different
number of consecutive channels. The protocol selection is set
in the Menu System. For information on setting a fixture to a
different protocol option, see User Mode Menu on page 30.
Setting a Start Channel
1. Turn on the menu system by pressing and holding the
Battery button for two seconds. The display will show
the current Function and Start Channel assigned to the
fixture.
2. Press the
MODE/ESC button to enter the first level of
the menu system. The display will show Address and
Info as the first two options in the top menu level.
The red star
*
indicates the current menu as you scroll
through the level using the
buttons.
The number at the bottom left of the display indicates
the Menu Level you are on. Address is the first option on
the first level.
3. Press the
Enter button to choose Address. The
currently selected Start Channel is displayed in white.
4. Use the
buttons to scroll to the desired start
channel and press
to select.
F u n c t i o n : D M X R e c e i ve
Address:
001
Menu: Press <Mode>
073F
Address:
01
Info
Address
01-01
001
MODE
/ ESC