Crank, No-Start
Step 10
Remove LP fuel hose from fuel rail fitting using line disconnect tool.
LP fuel line disconnected:
Proceed to Step 11.
line disconnect tool
Step 11
Install a commercially available fuel pressure test port adaptor and gauge rated for at least 150 psi
(10.3 Bar)
from fuel rail to LP fuel hose.
Test tool installed:
Proceed to Step 12.
Verify connections are secure by pulling fuel line connection firmly.
FRONT
Verify gauge is at least 150 psi
(10.3 Bar)
and CNG compatible.
LP hose
fuel line adaptor tool
ALWAYS verify fuel system has been depressurized!
Step 9
Continued
from Step 6
Depressurization complete:
Proceed to Step 10.
Depressurize fuel system; refer to Depressurization section of this manual.
Observe organizational LOTO practices; install lockout/tagout (LOTO)
devices.