DSM.0008 Ver 1.0
FCCC MT-45 / MT 55 CNG Diagnostics Service Manual
February 15, 2022
P
RINTED AND
D
OWNLOADED
C
OPIES ARE
N
OT
C
ONTROLLED
FCCC MT CNG
35
FCCC MT CNG
DSM.0008 Ver 1.0
FCCC MT-45 / MT 55 CNG Diagnostics Service Manual
February 24, 2022
P
RINTED AND
D
OWNLOADED
C
OPIES ARE
N
OT
C
ONTROLLED
35
Fuel Gauge Non-operation
Step 19
Continued
from Step 3.
Ignition
OFF
, with connector
C1
still disconnected.
Disconnect connector
F78
.
Measure resistance between connector
F78 Terminal B
(White) and connector
F78 Terminal D
(Pink).
Resistance is less than 10 ohms:
Repair short to power between circuit 315
and 204. Refer to DSM.0036.
Perform System Verification Procedure.
Resistance is greater than 10 ohms:
Suspected short to power on fuel level circuit of
chassis harness between F79 and OEM ECU
connector or a failed ECU.
Follow FCCC diagnostic procedure.
Perform System Verification Procedure.
A
D
C
B
DMM
Ω