3. Select the Serial Number field and press Enter.
The following alert appears:
The serial number is modified by qualified service personnel and must match
the serial number located on the chassis.
4. Click OK.
5. Type the serial number and press Enter.
6. Select the Product ID field and press Enter.
The following alert appears:
Product ID is modified only by qualified personnel. This value must match
the product ID located on the chassis.
7. Type the product ID and press Enter.
8. Press F10 to save the configuration.
The procedure is complete.
System battery replacement
System battery information
The server contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery that provides
power to the real-time clock. If this battery is not properly handled, a risk of the fire and burns exists. To reduce the risk of
personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not expose the battery to extremely low air pressure as it might lead to explosion or leakage of flammable liquid or
gas.
• Do not disassemble, crush, puncture, short external contacts, or dispose the battery in fire or water.
• If the server no longer automatically displays the correct date and time, then replace the battery that provides power
to the real-time clock. Under normal use, battery life is 5 to 10 years.
Removing and replacing the system battery
Prerequisites
Before you perform this procedure make sure that you have a flat-bladed, nonconductive tool.
Procedure
1.
If installed,
2.
3.
Remove all power:
Removal and replacement procedures