Adding Module #6 to a Five-Module Fabric
You have an existing fabric with five FM 3180 fabric modules. You want to add another FM 3180 to
make it a fabric of six. To add the fabric module, you need to shift six existing connections and add three
more cables.
You start changing connections with HPE FM 3180 3 55, then HPE FM 3180 4, next HPE FM 3180 5,
and finally number 6. The following table lists the re-cabling required by direction.
Cable Connection
Steps to accomplish
Module 3 55 to Module 6 56
1. Unplug Module 1 56
2.
Plug the freed end
into
Module 6
56
Module 4 53 to Module 6 54
3.
Unplug Module 1
54
4.
Plug freed end
into Module 6 54
Module 4 55 to Module 1 56
5.
Unplug Module 2
56
6.
Plug freed end into Module 1
56
Module 5 51 to Module 6 52
7.
Unplug Module 1 52
8.
Plug freed end into Module 6 52
Module 5 53 to Module 1 54
9.
Unplug Module 2 54
10.
Plug freed end into Module 1 54
Module 5 55 to Module 2 56
11.
Unplug Module 3 56
12.
Plug freed end into Module 2 56
Module 6 51 to Module 1 52
13.
Plug Module 6 51 to Module 1 52
Module 6 53 to Module 2 54
14.
Plug Module 6 53 to Module 2 54
Module 6 55 to Module 3 56
15.
Plug Module 6 55 to Module 3 56