84
HE 5750 Operating Instructions
#371627 Version 1.1
The controller offer two trend graphs:
Dust process via different time windows
Delta-p graph via different time windows
Dust process
The y-axis of the monitoring graph is dynamically scaled.
Delta-p graph
1
Display of dust process (switching via F12 key)
2
Measuring unit
3
Graphical display of monitoring time
4
Time lapse of display
5
Current time
6
Returning to the main menu via F4 key
7
Chamber / valve of the right time window of monitoring
8
Right triggered valve
9
Diagram scaling (%/mbar)
10
Display time start
11
Number of the displayed time window
12
Current dust or Delta-p value
13
Display time end
14
Symbol (I) for the time of valve triggering
◄► Time window selectable via arrow keys (to the left = earlier time)
▲▼ Displayed time lapse can be reduced / increased via the arrow keys:
Dust graph: 18 s, 90 s, 6 min, 30 min., Delta-p: 90 s, 6 min., 30 min., 2 h
F1 The recording is stopped in the display, but keeps on running in the background
F12 Switching between dust and Delta-p display