20
-
2.2
Interfaces
Lemo Contact is the default communication connector. (Another option is the Phoenix Contact, detailed in Appendix IV.)
Lemo part number: FGG.2T.316.CLAC75Z (male plug, on the lidar)
From the eye to
the interface
Figure 2.5 Lemo Connector (Male Plug)
Pin #
Signal
Color
Voltage
Pin #
Signal
Color
Voltage
1 ~ 4
-
-
-
11
Power
RED
9 to 48 V
5
Ethernet RX-
BLUE
-1 to 1 V
12
Power
GRAY
9 to 48 V
6
Ethernet RX+
BLUE/WHITE
-1 to 1 V
13
Ground (Return)
BLACK
0 V
7
Ethernet TX-
ORANGE
-1 to 1 V
14
Ground (Return)
GRAY/WHITE
0 V
8
Ethernet TX+
ORANGE/WHITE
-1 to 1 V
15
Index
PURPLE
0 to 3.3 V
9
GPS Serial Data
WHITE
-13 to +13 V
16
Encoder
PURPLE/WHITE
0 to 3.3 V
10
GPS PPS
YELLOW
TTL 3.3/5 V
For the GPS PPS signal, pulse width is recommended to be over 1 ms, and the cycle is 1 s (rising edge to rising edge)
Before connecting or disconnecting an external GPS signal (either using the cable's GPS wire or via the connection box's GPS port), make
sure the lidar is powered off. If the lidar has to stay powered on, make sure to:
· ground yourself in advance
· avoid touching the GPS wire or GPS port with bare hands
Summary of Contents for Pandar64
Page 1: ...www hesaitech com HESAI Wechat Pandar64 64 Channel Mechanical LiDAR User Manual ...
Page 17: ... 15 2 Setup 2 1 Mechanical Installation Figure 2 1 Front View Unit mm ...
Page 18: ... 16 Figure 2 2 Bottom View Unit mm ...
Page 19: ... 17 2 1 1 Quick Installation Figure 2 3 Quick Installation ...
Page 20: ... 18 2 1 2 Stable Installation Figure 2 4 Stable Installation ...
Page 28: ... 26 2 3 2 Connection Figure 2 10 Connection Box Connection with GPS ...
Page 29: ... 27 Figure 2 11 Connection Box Connection with PTP ...