Part Number 3080006.001, Rev. D
©2012, HES, Inc.
6
11
Electrically connect the
antenna/reader wire to the lock
body.
Make sure to correctly orient connector while
inserting it. It only goes in one way.
12
Install the battery and operational check.
12a. Install the battery, noting correct polarity position
12b. Wait approximately 10 seconds for the lock to initialize.
12c. Check that the knob cannot be rotated and that the unit is locked.
12d. Gently tuck the wires into the battery cavity.
12e. Install the battery cover by inserting and tightening the provided screws.
12f. Present a valid iClass or 125kHz prox credential to unlock the cabinet lock.
Note:
Note: See WEMN4 Aperio Programming Application for programming credential.
Note:
Always use new batteries installed with correct polarity.
Configure the lock before continuing! Refer to the
Aperio Technology Installation
Manual
for details.
13
Place the single-door Strike Plate
Template.
13a. Peel off the protective layer of the
Strike Plate Template and align it
to both the latch centerline and the
edge of cabinet.
13b. Drill two pilot holes as shown.
13c. Remove the template.
12d.
12a.
12e. Install battery and cover
.
12e. Install #2-56 screws
.