TW-800R-SCL/TW-800T
27
■10.Application interlock mode
A operating mode to be selected when using the receiver with POKAYOKE plus. When using the receiver in the
application interlock mode, configure the network settings of the receiver.
For details on network settings, see
"7-3-3. Setting network information".
10-1.Buzzer volume adjustment
When the receiver is not connected to POKAYOKE plus, the buzzer volume can be changed.
①
Long press the [setting (REG.)] key in the count mode for 3 seconds or longer. (The receiver cannot enter the
setting change mode during a task.)
②
The Receiver (RX) LED lights up in white. Set the counter to the desired buzzer volume level by using the
[setting (UP/DOWN)] keys.
Buzzer volume: 0
–4 (Volume 0 indicates no sound.)
③
Press the [setting (REG)] key, and the registration is completed.
10-2.Installation Methods
Connec
t the LAN connector of the receiver to the switching hub or the PC’s LAN connector with the LAN cable.
The receiver is not equipped with AutoMDI/MDI-X function to determine the LAN port. To connect the
receiver
to the PC’s LAN port directly, use a cross-wired LAN cable.
HUB
LAN cable
LAN cable (cross-wired)
Buzzer volume → Lit in white