TW-800R-SCL/TW-800T
21
7-3-4. Advanced settings
Click “Device Setup” in the Menu. Change the necessary items and click the [Submit] button.
Device Setup
Reg-ID List (Registered transmitter ID)
The paired transmitter ID is displayed.
*Transmitter ID is a 10-digit serial number shown on the label attached to the transmitter.
Device Setup
[Judge output time (PASS/FAIL)] Judge output time (PASS/FAIL) setting
Applies to output cable for Judge PASS output(red) and FAIL output (red/white).
An external output (open collector output) is generated for the set time from when the work is judged as
PASS or FAIL. Available from the following 12 different time settings.
50ms / 100ms / 150ms / 200ms / 300ms / 400ms / 500ms / 600ms / 700ms / 800ms / 900ms / 1s
Default:
100ms
Example) Action performed when specified count value of the work is set to 2 and the Judge output time is
set to 100ms and the work is judged as PASS after the work completion.
If the receiver is reset by pressing the reset button or by an external (Reset) input during Judge output, the
external output will stop.
Judge output (PASS) ON
Judge output (PASS) OFF
100ms
Receive
Receive
"Receive" indicates that a
signal from the transmitter
is received.
PASS