8.How to Use
8-1. Starting a Task with a Tool
①
Make sure Receiver (RX) LED is not lit. When Receiver (RX) LED lights up(green), this indicates the
receiver is not paired with a transmitter. Perform pairing.
For the pairing procedure, refer to "6-1-1. Pairing procedure".
②
Start work with the tool equipped with the transmitter. As you work, the transmitter will send a wireless
signal.
When the receiver receives a signal from the transmitter, it generates a data output via LAN. According to
the settings, an external output (open collector output) is generated and the buzzer sounds at the same
time. The green LED of transmitter turns on 1 time.
When the communication is not done normally, receiver doesn’t move. The red LED of transmitter blinks 10 times.
During double count prevention time or when the maximum number of data items to be stored is exceeded, the
receiver returns a “BUSY” signal to the transmitter. When the transmitter receives the “BUSY” signal, the green
LED of transmitter blinks 4 times.
Transmitter
Receiver
Communication OK
Green LED blinks 1 time
Receiver (RX) LED blinks 1 time
Communication NG
Red LED blinks 10 times
-
BUSY
Green LED blinks 4 times
-
*When the transmitter is not done “Pairing” transmits, the red LED blinks 3 times.
8-2. Checking the Remaining Battery Capacity and Communication
The transmitter is equipped with a test switch for communication and battery voltage checks. Receiver (RX) LED
is triggered by a signal from the test switch, but the receiver determines whether or not to generate an external
output (open collector output), according to the settings. When the test switch is pressed, the transmitter checks
the battery remaining capacity. The result is indicated by the LED of transmitter.
The test switch also can be used as a pairing switch. A long press on the test switch (3 seconds or more) resets
the pairing with the receiver and prevents communication with the registered receiver. When pairing is reset by
mistake, perform the pairing procedure again.
Transmitter
Receiver
Communication check
OK
:
Green LED blinks 1 time
NG
:
Red LED blinks 10 times
Receiver (RX) LED blinks 1 time
Battery level low
Red LED: Lighting for 1 second
Receiver (RX) LED blinks 1 time
*After display of the communication check result (Communication OK/ NG), the transmitter indicates battery level
low.
Test switch (pairing switch)