![Herutu TW-800R-SLNX Instruction Manual Download Page 11](http://html.mh-extra.com/html/herutu/tw-800r-slnx/tw-800r-slnx_instruction-manual_2127111011.webp)
TW-800R-SLNX
9
5.Installation
①
Install the receiver in a location where it can be seen well from the transmitter and can receive radio waves
stably. Install the receiver so that the side with various setting keys is facing the operator.
②
Connect the AC adapter plug to the power jack.
③
Connect the external output cable to the external output connector as required.
External output
An open collector output is used for external outputs. When output is turned ON, a short circuit occurs between
each terminal.
Be aware that the internal circuit may be damaged when the contact rated load is exceeded.
For external outputs, use the supplied “External output cable TW-SCLO-4”.
Rated load voltage:
DC24V
Rated load current:
0.1A
Contact structure/configuration:
NPN Transistor Open collector output
Connector:
Square connector
2.5mm pitch, 2×2 pins, 4 poles(1 pole unused)
[Output circuit]
Pin No.
Contents
Cable
1
Output 1
Red
2
Output 2
Two colors of red and white
3
Unused
Unused
4
COM
Black