TW-800R-SLNX
16
Reg-ID List (Registered transmitter ID)
The paired transmitter IDs are displayed.
*Transmitter ID is a 10-digit serial number shown on the label attached to the transmitter.
When pairing is not done, “0000000000” is displayed.
Device Setup
⚫
[Output 1/ Output 2] Output condition setting
For external outputs, use the supplied “External output cable TW-SCLO-4”.
Set the output condition for Output 1(red) and Output 2(red/white) for the external output cable.
The output condition can be set individually for Output 1(red) and Output 2(red/white).
Setting value
Contents
Disable
No output is generated at all.
All ID
Output is generated when a signal is received from the transmitter.
All of the paired transmitters are the target.
Transmitter ID
(10 digits)
Output is generated when a signal is received from the transmitter.
Default: The output condition is set to “Disable” before pairing is performed.
After pairing, the settings change automatically as follows.
Output 1 (red) is set to ID1 with the pairing transmitter ID, and Output 2 (red / white 2 colors) is set to ID2
with the pairing transmitter ID. Output 2 remains "Disable" if not paired with ID2.
When the pairing with the transmitter of the selected transmitter ID is canceled, it switches to "Disable".
⚫
[Output time] Output time setting
Available from the following 12 different time settings.
Applies to external output cable Output 1(red) and Output 2(red/white).
50ms / 100ms / 150ms / 200ms / 300ms / 400ms / 500ms / 600ms / 700ms / 800ms / 900ms / 1s
Default:
100ms
Example) Action performed when output time is set to 100ms
An external output (open collector output) is generated for 100ms from when a signal is received from the
transmitter.
100ms
External output ON
External output OFF
Receive
Receive
100ms