TW-800R-SLNX
20
7-2.Communication Specification
Ethernet Interface
Interface
RJ-45 Ethernet
10BASE-T or 100BASE-T, Duplex full or half
Compatibility
Ethernet Version 2.0 / IEEE802.3
Protocol
TCP/IP, UDP/IP
Ethernet output data types are classified into two types: “Short data” and “Long data”.
Set a data type with a Web server function. ([Device Setup] – “Data length Type”)
Long Data is short data added by extension region of 24bytes (Transmitter-specific data, etc.). When using the
extended region, please set to “long data”.
When not using the extended region, it is recommended set to “short data”.
◆
Formatting short data (19byte)
Preamble STX
Transmitter
ID number
Fastening information,
test switch battery
information
ETX
Checksum
Data name
Description
Byte
Preamble
FFH,FFH,FFH
3
STX
02H
1
Transmitter ID number
ID number 10 digit is converted to ASCII data(Hexadecimal).
Example) ”010100004A”
(30H,31H,30H,31H,30H,30H30H,30H,34H,41H)
10
Fastening information,
test switch battery
information
2 byte ASCII data
Transmission Limit switch signal “01” (30H,31H)
Transmission test switch (Battery voltage OK) “02” (30H,32H)
Transmission test
switch (Battery voltage low) “12” (31H,32H)
2
ETX
03H
1
Checksum
Calculated XOR from “Transmitter ID” to “ETX”. And it is
converted to ASCII data for 2byte.
2
*Sample of Checksum calculated
Transmitter ID number : 010100004A
Tightening information : Transmission Limit switch signal
“01” (30H,31H)
Checksum→(37H,37H)