Fault table
Fault
Cause
Remedy
Overflow valve
does not respond
Covers have not been
removed;
Remove covers.
Test pressure too high;
Replace the overflow valve.
Back pressure not taken into
account;
Replace the overflow valve.
Not liftable
Pressure below 85% of the set
pressure;
Lifting in the range ≥85 % of the set
pressure without aids.
Leak in the seating
Foreign bodies between cone
and seating, contaminated
medium;
Remove foreign bodies by briefly
lifting / flush the system or replace
the overflow valve.
Seating damaged;
Replace the overflow valve.
Cone seal damaged;
Replace the overflow valve.
Overflow valve has fluttered;
See “Chattering”.
Damage to the
inlet/outlet
Transport damage;
Replace the overflow valve.
Wrong connecting thread /
tightening torque too high;
Replace the overflow valve.
Impermissible forces such as
bending or torsional forces are
being transmitted;
Install stress-free.
Shock waves
Overflow valve not fitted at the
highest point;
Install the overflow valve at the
highest point.
water not drained correctly or
at all;
Attach water drain according to
regulations.
Constantly blowing
off
Spring corroded by
impermissible medium and
broken;
Replace the overflow valve.
System pressure too high
Replace the overflow valve.
Seal damaged;
Replace the overflow valve.
Chattering
Pressure drop in the inlet line
>3%;
Reduce resistance through chamfer
or radius in the connecting socket;
choose a larger one if necessary.
Shorter inlet line.
Incorrect overflow valve, replace it.
Seals for inlet and outlet
connector too small or not
installed centrally;
Change conditions.
overflow valves are too highly
rated;
Select smaller overflow valves.
Outlet line too long or diameter
too small;
Use a larger nominal diameter or a
back-pressure-compensating
stainless steel bellows. The max.
height is to be specified by the
manufacturer.
Inlet or outlet connector too
small;
Dimensions must be larger than the
nominal inlet or outlet diameter.
Back pressure higher than 3%;
Use back-pressure-compensating
stainless steel bellows. The max.
height is to be specified by the
manufacturer.
Inadequate
capacity
overflow valves incorrectly
configured for the plant
conditions;
Re-dimension and replace the
overflow valve.
Overflow valves not being used
in accordance with the
applicable regulations;
Change conditions.
Summary of Contents for 06001
Page 2: ......
Page 6: ......
Page 18: ...Betriebsanleitung 12 Telefon 49 4531 509 0 ...
Page 30: ...Operating instructions 24 Phone 49 4531 509 0 ...
Page 42: ...Instrucciones de servicio 36 Teléfono 49 4531 509 0 ...
Page 54: ...Notice d utilisation 48 Téléphone 49 4531 509 0 ...
Page 66: ...Руководство по эксплуатации 60 Телефон 49 4531 509 0 ...
Page 79: ...使用说明书 herose com 73 ...
Page 81: ...HEROSE GMBH ARMATUREN UND METALLE herose com II Notizen Note Apunte Note заме тка 杂记 ...
Page 83: ...HEROSE GMBH ARMATUREN UND METALLE herose com IV Notizen Note Apunte Note заме тка 杂记 ...