3 -OPERATION
DESCRIPTION OF THE DISPLAY
DESCRIPTION OF THE KEYBOARD
The Nature Compact appliance has been
equipped with an electronically controlled forced
convection fan and combustion air intake valve.
In order to adjust the settings, point the remote
control towards the appliance.
The infra-red receiver is located at the bottom
left of your appliance.
FAN
The fan can be adjusted in two ways:
-
Automatic:
This mode has precedence over the
manual mode.
In this mode, the fan will operate at speed 1
(1/3
of the fan's full speed) when the temperature
probe reaches
40ºC.
Two safety measures are enables in this mode.
When the probe reaches a temperature of 70ºC,
the fan will operate at speed 2
(2/3 of the fan's
full speed).
When the probe detects a temperature of 90ºC,
the fan will operate at full speed and return to
speed 2 when the probe detects that the
temperature drops below 85ºC.
-Manual:
In order to adjust the fan, select this
option using the
MODE
button
This will
enable you to increase the speed of the fan by
pressing the
FAN
button and selecting one
of the four options
AUTO
/
MINIMUM
/
MEDIUM
/
MAXIMUM
.
When operating
the device manually, you may increase the speed
of the fan in relation to the speed selected by the
automatic function,
you will not be allowed to
reduce the speed of the fan below the speed
established by the automatic function or stop
the fan if the automatic function is connected.
If you activate the fan when there is no
temperature, the fan will stop two hours after
the last time the remote control was used
COMBUSTION AIR ADJUSTMENT.
When the compact device is plugged into a
power socket, the valve resets into the open
position. This operation takes place whenever
the device is unplugged and then plugged in
again or when the power supply is re-
established after a power cut.
- Use the valve option in the
MODE
selector
to adjust the valve.
Once the symbol appears on
the display, use
^ TEMP+
to open the valve and
˅
TEMP-
to close the valve
(press repeatedly until
the desired valve position appears on the
display)
The motorised valve has 5 defined positions.
These positions are displayed by means of a
series of horizontal bars.
VALVE CLOSED
VALVE OPEN ¼
VALVE OPEN 2/4
VALVE OPEN ¾
VALVE FULLY OPEN
Summary of Contents for NATURE 100
Page 11: ...FIG 15 Posición original FIG 16 Posición original FIG 17 Posición modificada ...
Page 21: ...FIG 15 Posizione originale FIG 16 Posizione originale FIG 17 Posizione modificata ...
Page 40: ...FIG 15 Position originale FIG 16 Position originale FIG 17 Position modifiée ...
Page 50: ...FIG 15 Posição original FIG 16 Posição original FIG 17 Posição modificada ...
Page 52: ...11 16 12 17 13 18 14 19 15 ...
Page 54: ...6 9 10 7 8 9 ...
Page 56: ...NATURE 70 ...
Page 57: ...NATURE 80 NATURE 80 ...
Page 58: ...NATURE 80 NATURE 100 ...
Page 61: ...NATURE 80 ...
Page 62: ...NATURE 80 ...