General information
10
Ambient temperature range for:
lower limit temperature: - 5 °C
upper limit temperature: + 40 °C
Density and viscosity of the pumped medium:
Density:
max. 1000 kg/m
3
Kinematic viscosity:
max. 1 mm
2
/s (1 cST)
Customised solutions may differ from this standard data.
Power correction:
Reduce the power according to the specifications of the mo-
tor manufacturer if motors are used at ambient temperatures
> 40 °C or at altitudes > 1000 m above sea level.
A differing density or viscosity alters the hydraulic perform-
ance of the pump. Observe the motor performance with
these media.
Sound pressure level:
The sound pressure level dB(A) of the pump during cavita-
tion-free operation lies within the range of Q
optimal
below the
limit values specified in EC Machinery Directive 2006/42/
EC.
Model X
50/60 Hz
P2 [kW]
1500/1800 min
-1
1.1/1.3
55/59
1.5/1.8
55/59
2.2/2.6
59/63
3.0/3.6
59/63
4.0/4.8
59/63
5.5/6.6
63/67
7.5/9.0
63/67
11.0/13.2
65/69
15.0/18.0
65/69
18.5/22.2
65/69
22.0/26.4
67/71
30.0/36.0
68/72
37.0/44.4
70/74
45.0/54.0
70/74
55.0/66.0
71/75
Motor data for model X-PM
Design
IM B5
Motor connection
Manufacturer-specific
Protection type
IP 55
Speed
1500 min
-1
Connection
3
300 - 400 V
Insulation class VDE 0530
F
Customised solutions may differ from this standard data.
1.4.6 Dimensions, weight, performance data
The measurements, installation dimensions and weight de-
tails can be found in section 5.2 'Dimensions'. The instruction
documents and the name plate data specify the performance
and connection data of the respective pump type.
The performance verification of the pumps is performed ac-
cording to DIN EN ISO 9906 (Rotodynamic pumps - Hydraulic
performance acceptance tests), Class 2.
1.4.7 General data
Media temperature range for:
lower limit temperature: - 5 °C
upper limit temperature: + 60 °C
Caution!
In type UNIBAD-XC pumps, pumped
media < 15°C and > 40°C damage
the motor.
Connect another cooling circuit to the
motor.
Summary of Contents for UNIBAD-X