10-SSI-001_rev.005_ENG
Page
29
of
51
The definitive number of modules connected in parallel depends on the plant topology
(Inverter sizing according to known practice, protection means, etc). To avoid electrical shock,
ground the understructure of the module before wiring the circuit, using a grounding method that
meets the appropriate standards or directive requirements for grounding solar electrical
systems. Such grounding means shall be isolated from live parts by reinforced insulation.
The solar cables are equipped with the MultiContact pin-and-socket connector system
for PV.
The plugs are marked with the respective polarity. The MINUS pole is minus-coded, the
PLUS pole plus-coded.
The junction box with cables, assembled in the factory for the electrical connection of the
modules, must never be opened.
If additional cables are needed, use only appropriate cables.
The solar modules generate electricity when exposed to sunlight. Take care not to short
circuit the output cables. The cables can become overheated and their cables sheaths
can melt.
Make sure
you don’t overstretch the Junction Box cables as shown in the following
pictures, to avoid water penetration into the Junction Box.
Fig. 26 Junction Box cables stretching
Be absolutely sure to interconnect
the modules’ according to the correct polarity. Reverse
polarity may destroy the protective diodes!
Consult local codes, applicable laws and statutes concerning required permits and
regulations regarding installations and inspection requirements. Install solar modules and
systems according to applicable codes.
Right
Wrong
Summary of Contents for HS Atlas Series
Page 1: ...10 SSI 001_rev 005_ENG Page 1 of 51 SAFETY AND INSTALLATION INSTRUCTIONS...
Page 38: ...10 SSI 001_rev 005_ENG Page 38 of 51 Fig 27 Laser marking 2D barcode Fig 28 Module label...
Page 43: ...10 SSI 001_rev 005_ENG Page 43 of 51 12 CERTIFICATES 12 1 Modules...
Page 44: ...10 SSI 001_rev 005_ENG Page 44 of 51...
Page 45: ...10 SSI 001_rev 005_ENG Page 45 of 51...
Page 46: ...10 SSI 001_rev 005_ENG Page 46 of 51...
Page 47: ...10 SSI 001_rev 005_ENG Page 47 of 51 12 2 Junction boxes...
Page 48: ...10 SSI 001_rev 005_ENG Page 48 of 51 12 3 Cables...
Page 49: ...10 SSI 001_rev 005_ENG Page 49 of 51 12 4 Connectors...
Page 50: ...10 SSI 001_rev 005_ENG Page 50 of 51 12 5 Factory Inspection...
Page 51: ...10 SSI 001_rev 005_ENG Page 51 of 51 12 6 Quality Management System...