6. ELECTRICAL INSTALLATION
As shown in section
5 “Mechanical installation” HS modules must be installed in “portrait”
position.
For optimum system performance, partial shading on modules must be avoided. In
particular, long term or repetitive shading parallel to the cells may lead to irreversible module
damage.
Module damage resulting from installation and/or system design faults is not covered by
module warranty.
Modules may be connected in series and/or parallel to achieve the desired electrical
output as long as certain conditions are met.
Series connection of modules
All modules connected in series must have identical orientation and inclination and belong
to the same type and power category. In series connection the overall voltage of the string is
equal to the sum of the voltage of each module. Never exceed the limit of 1000V on connected
modules. Voc of modules at low temperatures (below 0
°
C) should be taken into account. Thus,
a maximum of 6 modules may be connected in series (when using inverter with 1000V max DC
input voltage).
Contact HelioSphera engineers if you are not sure for the total number of
modules you can connect in series, with any specific inverter you are going to use
.
Fig. 20 Series connection of modules (back view)
Parallel connection of strings
All strings connected in parallel should consist of modules with identical orientation and
inclination. In parallel connection the overall current is equal to the sum of the current of each
string/module. In order to avoid/eliminate reverse currents a maximum of 3 strings can be
paralleled without the use of a fuse or a blocking diode. In case that more than 3 strings must be
paralleled, then follow one of the following solutions (in any case use appropriate fuse/diode
type, i.e. 1000V DC):
Summary of Contents for HS Atlas Series
Page 1: ...10 SSI 001_rev 005_ENG Page 1 of 51 SAFETY AND INSTALLATION INSTRUCTIONS...
Page 38: ...10 SSI 001_rev 005_ENG Page 38 of 51 Fig 27 Laser marking 2D barcode Fig 28 Module label...
Page 43: ...10 SSI 001_rev 005_ENG Page 43 of 51 12 CERTIFICATES 12 1 Modules...
Page 44: ...10 SSI 001_rev 005_ENG Page 44 of 51...
Page 45: ...10 SSI 001_rev 005_ENG Page 45 of 51...
Page 46: ...10 SSI 001_rev 005_ENG Page 46 of 51...
Page 47: ...10 SSI 001_rev 005_ENG Page 47 of 51 12 2 Junction boxes...
Page 48: ...10 SSI 001_rev 005_ENG Page 48 of 51 12 3 Cables...
Page 49: ...10 SSI 001_rev 005_ENG Page 49 of 51 12 4 Connectors...
Page 50: ...10 SSI 001_rev 005_ENG Page 50 of 51 12 5 Factory Inspection...
Page 51: ...10 SSI 001_rev 005_ENG Page 51 of 51 12 6 Quality Management System...