74
249
time
2
250
THERMIC
SENS KO
Temperature
sensor fault
The output signal of controller temperature sensor
exceeds range.
Change the controller.
2
251
WRONG SET
BATTERY
Battery setting
fault
When starting, controller checks battery voltage if it is
within the nominal range. Check if the “BATTERY
VOLTAGE” parameter in TESTER is the same
with the value shown on the voltmeter. If they are not
the same, adjust the battery voltage through
“ADJUST BATTERY” to be the same with measured
value.
Change the battery.
2
253
SLIP PROFILE
Slip frequency
fault
slip profile parameter select error.
Check these values setting in hardware setting
parameter.
2
254
AUX
DRIVER
SHORTED
Auxiliary
driver
short
circuit
Electromagnetic brake or auxiliary electric brake’s
drive circuit has short circuit.
Check if there is short circuit between A16 and –BATT
or low impedance discourages output.
Logic card’s driver electric circuit has fault, change the
controller.
3) Pump control system common fault (PU node displayed on meter)
Fault
code
Meaning
explanation
Remedy
1
13
EEPROM KO
Damage
of
programmable
memorizer
Fault in the area of memory in which the adjustment
parameters are stored; this alarm inhibits machine
operation. If the defect persists when the key is
switched OFF and ON again, replace the logic. If the
alarm disappears, remember that the parameters stored
previously have been cancelled and replace by the
default values.
1
17
LOGIC FAILURE
#3
LOGIC
FAILURE #3
Fault in the hardware section of the logic board which
manages the hardware current protection. Replace the
controller.
1
18
LOGIC FAILURE
#2
LOGIC
FAILURE #2
Fault in the hardware section of the logic board which
manages the
Phase’s voltage feedback. Replace the controller.
1
19
LOGIC FAILURE
#1
LOGIC
FAILURE #1
This alarm signals that an undervoltage /overvoltage
protection operation has occurred. The voltage detected
by controller higher than 65V or lower than 11V.