3 Functions
Digital Governor Basic System PANDAROS II
9
i)
PWM inputs
The multifunctional ports (terminals 1 and 2) and digital input 3 can also be config-
ured as PWM inputs. In this way, every available analogue measured value or calcu-
lated setpoint can be output.
j)
PE module adjustment
Via CAN bus, it is possible to communicate with an additional PE module of type
DC 6. This can then control a second actuator and provide additional inputs and out-
puts that can be configured from the speed governor. The typical application in this
regard is the control of V-type engines with two actuators.
3.2.6
Variation DC 6-06 (positioner)
This variant does not feature an integrated speed governor. In this context, the corre-
sponding actuator is controlled via an actuator setpoint position signal received from an
external source. This variant is described in a dedicated publication.