3 Functions
8
Digital Governor Basic System PANDAROS II
3.2.5
Variation DC 6-00 (ful flexibility)
This variant is not pre-configured and contains all the previously described functions of
the different variants.
The only option that is not provided is that of communication with the digital generator
management THESEUS via CAN bus.
This variant continues to feature the following additional functions:
a)
Second speed sensor
A digital input can be reconfigured in order to support the use of a second speed sen-
sor (featuring a Hall design).
b)
Second fixed speed
It is possible to assign a second fixed speed.
c)
Setpoint selection via notches
For simple applications for locomotive operation, the speed setpoint selection can be
performed via notches. In this context, the bit combinations of up to four digital in-
puts can be assigned to corresponding speed setpoints.
d)
Changeover between limiting curves
It is possible to switch between two different limiting curves.
e)
Jet Assist
A Jet Assist function can also be activated in order to perform quick adjustments for
load compensation at low levels of boost pressure.
f)
Analogue outputs
The multifunctional ports (terminals 1 and 2) can also be configured as analogue
outputs featuring 4 … 20 mA. In this way, every available analogue measured value
or calculated setpoint can be output.
g)
PWM outputs
The multifunctional ports (terminals 1 and 2) can also be configured as PWM out-
puts. In this way, every available analogue measured value or calculated setpoint can
be output.
h)
Digital outputs
The multifunctional ports (terminals 1 and 2) can also be configured as digital out-
puts. This makes it possible for every digital measured value to be output.